摘要
利用MSA技术研究静水压爆破测量系统的变差对测量结果的影响,通过分析测量系统的偏倚、线性、稳定性、重复性和再现性进行质量控制,是一种行之有效的控制方法,应用统计学理论知识预测静水压爆破测量系统是否有能力满足测量要求,确保测量数据的质量。
The effects of pressure difference from Hydrostatic burst measurement system on the measuring result were studied with applicadon of MSA technology. The quality control can be realized through analysis about the deviation, linearity, stability, repeatability, and reproducibility of measurements system, which is an effective control method. The hydrostatic burst measurcment system is evaluated if the system can work properly and guarantee the quality of measured data per statistics principles.
作者
范炜
崔艳霞
孟丹
韩新利
黄呈帅
FAN Wei CUI Yanxia MENG Dan HAN Xinli HUANG Chengshuai(CNPC Tubular Goods Research Institute, State Key latboratory of Performance attd Structural Safety for lYtroleum Tubular Coods and Equipment Materials, Xi'an, Shaanxi 710077, China)
出处
《石油管材与仪器》
2017年第2期52-54,57,共4页
Petroleum Tubular Goods & Instruments
关键词
静水压爆破试验
质量控制
控制图
hydrostatic hurst test
quality control
control chart