期刊文献+

10kV配电系统中性点接地方式选取的有效性分析 被引量:11

Validity Analysis of Neutral Grounding Mode Selection in 10kV Power Distribution System
下载PDF
导出
摘要 针对10k V配电系统小电流接地方式和故障选线装置的选取,文章对国内中性点接地方式和选线装置基本原理、优缺点以及应用情况进行了梳理总结,并对不同接地方式下不同选线原理装置进行了RTDS仿真和现场试验测试,测试结果表明:不接地方式下,暂态法选线装置选线准确率较高;消弧线圈接地方式下,暂态法和稳态法选线准确率均较低,无法满足选线要求。 For the issue of selection of Small current neutral grounding mode and fault line selection technologies in lOkV distribution power system, this paper summarizes the basic principle, advantages and disadvantages, and applications of the neutral point grounding mode and the line selection devices. In addition, this paper has also carried out RTDS simulation and field tests for different fault line selection devices in different neutral grounding types. The results show that fault line selection devices developed with transient technology has higher accuracy than stationary technology in non-grounding system. However, the performance of both technologies is not good in arc-suppression coil grounding system.
作者 袁耀 邹林 喇元 王颂 李锐海 YUAN Yao ZOU Lin LA Yuan WANG Song LI Ruihai(Electric Power Research Institute, CSG, Guangzhou 520080, China China Southern Grid, Guangzhou520080, China)
出处 《供用电》 2017年第5期7-13,共7页 Distribution & Utilization
关键词 中性点 接地方式 故障选线 配电系统 Neutral point grounding system faulty line selection distribution system
  • 相关文献

参考文献17

二级参考文献154

共引文献775

同被引文献94

引证文献11

二级引证文献20