期刊文献+

Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens 被引量:7

Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
下载PDF
导出
摘要 AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering. AIM:To evaluate the clinical outcomes of V4 c implantable collamer lens(Hole ICL) implantation with regard to the optical quality assessed according to different degrees of decentering.METHODS:This included 49 eyes that received conventional ICL and 94 eyes that received Hole ICL.The eyes that received Hole ICL were divided into three groups according to the degree of decentering:group 1,central hole within 1 hole diameter(HD) from the pupil center;group 2,central hole within 1 HD to 2 HD;and group 3,central hole within 2 HD to 3 HD.Visual acuity(VA),intraocular pressure(IOP),and spherical equivalent(SE) values were assessed at 1wk,1 and 3mo after surgery.The ocular modulation transfer function,Strehl ratio,objective scattering index,and higher order aberrations(HOAs) were measured for 4-mm pupils at 3mo after surgery.RESULTS:There were no significant differences in VA,IOP,and SE among the conventional and Hole ICL groups.With regard to HOAs,values for coma and spherical aberrations showed no differences.The total HOA and trefoil values were significantly higher in group 2 than in group 1(P=0.02,0.03,respectively).There were no significant differences among groups with regard to other optical quality parameter at 3mo after surgery.CONCLUSION:Our results suggest that Hole ICL implantation provides satisfactory visual quality that is equivalent to that provided by conventional ICL,regardless of the presence of central hole and degree of decentering.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期619-623,共5页 国际眼科杂志(英文版)
关键词 implantable collamer lens optical quality phakic IOL refractive surgery implantable collamer lens optical quality phakic IOL refractive surgery
  • 相关文献

同被引文献39

引证文献7

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部