期刊文献+

高速公路服务区建筑供热水供暖方案对比研究 被引量:2

A Comparative Study on the Schemes of Hot Water Supply and Heating to Three Buildings in an Expressway Service Area
下载PDF
导出
摘要 根据创建的太阳能-垂直埋管式土壤源热泵供热水供暖联供系统,针对榆林地区某高速公路服务区建筑,以费用年值和系统COP为评价指标,利用TRNSYS软件模拟分析,对比研究了三种供热水供暖方案的系统经济性和能效,并讨论了电价对这三种方案经济性的影响。结果表明:1)水平分供式、垂直分供式和垂直联供式三种供热水供暖方案均可行;2)初投资:水平分供式<垂直分供式<垂直联供式,年运行费用:水平分供式>垂直分供式>垂直联供式,费用年值:水平分供式>垂直分供式>垂直联供式;3)系统COP:水平分供式<垂直分供式<垂直联供式;4)综合分析可知,联供方案优于垂直分供方案,垂直分供方案优于水平分供方案,且电价越高(高于0.3元/kWh时),优势越明显。 Based on the self-designed vertical borehole solar-ground source heat pump system supplying hot water andheating, authors of the article took the expressway service area buildings in Yulin as the research object, and took annualcost and system COP as evaluation index, and compared the three schemes of supplying hot water and heating throughthe TRNSYS simulation analysis, and discussed the influence on the economic analysis coming from the electricity price.The results showed that: 1) the horizontal independent supply type, the vertical independent supply type and the verticalcombined supply type are all feasible; 2) the investment cost: the first one 〉 the second one 〉 the third one, the annualoperating cost: the first one 〈 the second one 〈 the third one. Taking the investment cost and the operating cost intoaccount, the annual cost: the first one 〈 the second one 〈 the third one, 3) the system COP: the first one 〈 the secondone 〈 the third one; 4) when the annual cost and the system COP are considered, the first type is superior to the secondtype, the second type has an advantage over the third type, and the higher the electricity price (when over 0.3YuargkWh), the greater the superiority.
作者 罗贤吏 王智伟 刘炜 张明远 LUO Xian-li WANG Zhi-wei LIU Wei ZHANG Ming-yuan(School of Environment and Municipal Engineering, Xi' an University of Architecture & Technology Hanzhong Management Office of Baohan Highway)
出处 《建筑热能通风空调》 2017年第4期59-63,共5页 Building Energy & Environment
基金 陕西省交通运输厅2015交通科研项目(15-30K)
关键词 高速公路服务区 热泵系统 TRNSYS 费用年值 COP expressway service area, heat pump system, TRNSYS, annual cost, COP
  • 相关文献

参考文献6

二级参考文献17

  • 1李赟,黄兴华.冷热电三联供系统配置与运行策略的优化[J].动力工程,2006,26(6):894-898. 被引量:43
  • 2毕月虹.太阳能-土壤热源热泵用于冬季供暖的性能研究(硕士学位论文)[M].天津:天津大学,1995..
  • 3肖益民.地源热泵空调系统的设计施工方法及应用实例[J].现代空调,2001,(3).
  • 4谢汝镛.地源热泵系统的设计[J].现代空调,2001,(10):33-73.
  • 5毕月虹,硕士学位论文,1995年
  • 6Mei V C,ASME Trans J Sol Energy Engng,1988年,110卷,1期,67页
  • 7美国供暖制冷空调工程师学会 徐伟译 郎四维 校.地源热泵工程技术指南[M].北京:中国建筑工业出版社,2001..
  • 8Oklahoma state university,Geothermal heat pumps: in troductory guide,Oklahoma stateuniversity,1997
  • 9Cao J. Thermodynamic analysis of a combined cooling, heat and power generation system [A]. In: Proceeding of 15th international Conference ECOS2002[C]. Berlin (Germany), 2002:365-372
  • 10Tanton, D M, Cohen R R, Probert S D. Improving the effectiveness of a domestic central-heating boiler by the use of heat storage [J]. Applied Energy, 1987, 27(1): 53-82

共引文献132