摘要
介绍了镇江新区行政服务中心空调冷热源、风系统和水系统的设计方案;阐述了地埋管地源热泵系统加常规电制冷机组的复合冷源设计;结合绿色三星设计评价标准,分析了冷热源非传统水源的利用;指出了地埋管地源热泵系统的设计方法和应注意的问题。
The design of air-conditioning cooling and heat sources, air system and water system of Zhenjiang NewDistrict Administrative Service Center was introduced, and a compound cold source with buried pipe ground source heatpump system and electric refrigeration unit was designed. In combination with green 3 stars design evaluation standard,heat and cold sources of non-traditional water use is analyzed. Finally, the exchanger of ground source heat pump systemdesign method and some problems that should be paid attention to was pointed out.
作者
孙梅
赵祺
SUN Mei ZHAO Qi(Zhongxu Planning & Architecture Design Co., Ltd. China Architectural design institute Co., Ltd.)
出处
《建筑热能通风空调》
2017年第4期84-86,93,共4页
Building Energy & Environment
关键词
地埋管地源热泵
复合能源
绿色三星
节能
ground source heat pump exchanger, compound energy, Green 3 Stars, energy saving