期刊文献+

CRT电极经房间隔穿刺植入左室心内膜起搏心电图1例

A case of Transseptal endocardial left ventricular pacing for cardiac resynchronization therapy electrocardiogram
下载PDF
导出
摘要 将左室电极行房间隔穿刺植入左室内膜,对1例完全性左束支传导阻滞患者进行同步化治疗。常规心电图示Ⅰ导联主波为负向波,Ⅱ、Ⅲ、AVF呈R型,V1导联呈rS型,QRS时限进一步缩小为0.12s,心电图诊断为窦性心律,双心室起搏,心电图各导联QRS形态和时限具有一定的特征,行心内膜起搏的CRT患者的心电图分析具有重要价值。 The left ventricle electrode was implanted into atrial septal puncture,with complete left bundle branch block patients for cardiac resynchronization therapy ( CRT ) .The electrocardiogram I lead showed main wave negative wave, II,III,AVF is R,V1 lead was rS type, QRS duration further reduced to 0.12s,ECG diagnosis of sinus rhythm,biventricular pacing, electrocardiogram of the lead QRS morphology and time have certain characteristics for cardiac pacing in patients with CRT.The analysis of ECG is of great value.
作者 仇鑫
出处 《安徽卫生职业技术学院学报》 2017年第2期155-156,共2页 Journal of Anhui Health Vocational & Technical College
关键词 同步化治疗(CRT) 房间隔穿刺 心内膜起搏 Cardiac resynchronization therapy (CRT) Transseptal Left ventricular pacing
  • 相关文献

参考文献3

二级参考文献38

  • 1McMurray JJ, Adamopoulos S, Anker SD, et al. ESC guidelines for the diagnosis and treatment of acute and chronic heart failure 2012: The Task Force for the Diagnosis and Treatment of Acute and Chron- ic Heart Failure 2012 of the European Society of Cardiology. Devel- oped in collaboration with the Heart Failure Association ( HFA ) of the ESC [J]. Ear Heart J, 2012, 33(14) :1 787.
  • 2Yu C M, Fang J MH, Zhang Q, et al. Understanding nonresponders of cardiac resynchronization therapy current and future perspectives [J]. J Cardiovasc Electrophysiol, 2005, 16(10): 1 117.
  • 3Saxon LA, Olshansky B, Volosin K, et al. Influence of left ventric- ular lead location on outcomes in the COMPANION study [ J ]. J Cardiovasc Electrophysiol, 2009, 20(7 ) :764.
  • 4Gras D, Bcker D, Lunati M, et al. Implantation of cardiac resyn- chronization therapy systems in the CARE-HF trial: procedural suc- cess rate and safety [J]. Europace, 2007, 9(7) :516.
  • 5Bortone A, Macia JC, Leclercq F, et al. Monomorphic ventricular tachycardia induced by cardiac resynchronization therapy in patient with severe nonischemic dilated cardiomyopathy [ J ]. PACE, 2006, 29(3) :327.
  • 6Leon AR, Abraham WT, Curtis AB, et al. Safety of transvenous cardiac resynchronization system implantation in patients with chron- ic heart failure: combined results of over 2,000 patients from a mul- ticenter study program [J]. J Am Coil Cardiol, 2005, 46(12) :2 348.
  • 7van Deursen C, van Geldorp IE, Rademakers LM, et al. Left van- tficular endocardial pacing improves resyncbronization therapy in ca- nine left bundle-branch hearts [ J ]. Cite Arrhythm Electrophysiol, 2009, 2(5) :580.
  • 8Strik M, Rademakers LM, van Deursen C J, et al. Endocardial left ventricular pacing improves cardiac resynchronization therapy in chronic asynchronous infarction and heart failure models [ J ]. Cire Arrhythm Electrophysiol, 2012, 5 (1) :191.
  • 9Scott PA, Yue AM, Watts E, et al. Transseptal left ventricular en- docardial pacing reduces dispersion of ventricular repolarization [J]. Pacing Clin Electrophysiol, 2011, 34(10) :1 258.
  • 10Derumeaux G, Ovize M, Loufoua J, et al. Assessment of nonunifor- mity of transmural myocardial velocities by color-coded tissue Doppler imaging: characterization of normal, ischemic, and stunned myocardium [ J ]. Circulation, 2000,101 (12) : 1 390.