在分析天津地区Ⅱ-Ⅴ深层含水组含水层富水性、水温、水质和水位埋深条件基础上,研究地下水源热泵的适宜性,为地下水分区管理提供科学依据。
The research of groundwater source heat pump suitability based on the analysis of water yield property, water temperature, water quality and water depth condition of Tianjin region the second to the fifth deep water aquifer. This paper provides scientific basis for the partition management of groundwater.
出处
《水科学与工程技术》
2017年第2期67-69,共3页
Water Sciences and Engineering Technology
关键词
地下水源热泵
单井回灌量
热交换层位
深层岩水
groundwater source heat pumps
quantity of standing column well
horizon of heat exchange
deep aquifer