肥胖患者80kV不同级别迭代重建技术CTPA图像质量分析 被引量:1

CTPA image quality analysis of different level iterative reconstruction with 80 kV in obese patients
下载PDF
导出
摘要 目的评估80kV条件下不同级别迭代重建技术对肥胖患者CT肺动脉造影(CTPA)图像质量的影响。方法收集临床疑似肺栓塞并行CTPA检查的肥胖患者40例,采用滤波反投影(FBP)及3个级别的迭代重建技术(iDose^1:20%IR/80%FBP;iDose^3:40%IR/60%FBP;iDose^5:60%IR/40%FBP)重建图像。测量图像的肺动脉主干、右肺上叶动脉及右肺下叶后基底段动脉CT值、噪声,计算并比较4组数据的噪声、SNR及CNR。结果 4组重建图像噪声、SNR及CNR差异均有统计学意义(P均<0.001),图像噪声两两比较差异均有统计学意义(P均<0.05);FBP组的SNR及CNR与iDose^3组和iDose^5组比较,差异有统计学意义(P<0.01)。结论与FBP比较,80kV联合不同级别IR技术可明显降低CTPA图像噪声,提高图像质量,并可进一步降低肥胖患者接受的辐射剂量。 Objective To assess the effects of different level iterative reconstructions (IR) on image quality of obese patients of 80 kV CT pulmonary angiography (CTPA). Methods Forty obese patients with clinically suspected pulmonary embolism were examined with CTPA, filtered back projection method (FBP) and three IR levels (iDose1, 20% IR/80% FBP; iDose3, 40% IR/60% FBP; iDose5, 60% IR/40% FBP) to reconstruct images were used. The CT value of pulmonary artery trunk, upper lobe artery and lower lobe basal segment artery of right pulmonary were measured, and the image noise, SNR and CNR of four groups were calculated and compared. Results The image noise, SNR and CNR had significant difference in 4 groups (all P〈0.05), and the image noise had significant difference between each two groups (all P〈0.05), the SNR and CNR had statistical difference between FBP and iDose3, between FBP and iDose5 (P〈0.01). Conclusion Compared with FBP, 80 kV combined with different level IR technologies can significantly decrease image noise and improve objective image quality in CTPA, the radiation dose that obese patients received can be reduced.
出处 《中国介入影像与治疗学》 CSCD 北大核心 2017年第5期306-309,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 体层摄影术 X线计算机 迭代重建 噪声 肥胖 低管电压 Tomography, X-ray computed Iterative reconstruction Noise Obesity Lower tube voltage
  • 相关文献

参考文献6

二级参考文献95

  • 1李真林,杨志刚,郭应坤,余建群,李媛,陈宪,谈伟.管电流调制技术在多层螺旋CT胸部检查中的应用评价[J].中国医学影像技术,2006,22(6):858-860. 被引量:7
  • 2Heyer CM,Mohr PS,Lemburg SP,et al.Image quality and radiation exposure at pulmonary CT angiography with 100-or 120-kVp protocol:prospective randomized study.Radiology,2007,245(2):577-583.
  • 3Matsuoka S,Hunsaker AR,Gill RR,et al.Vascular enhancement and image quality of MDCT pulmonary angiography in 400 cases:comparison of standard and low kilovoltage settings.AJR Am J Roentgenol,2009,192(6):1651-1656.
  • 4ICRP.The 2007 recommendations of the international commission on radiological protection.ICRP publication 103.Ann ICRP,2007,37(2-4):1-332.
  • 5Kubo T,Lin PJ,Stiller W,et al.Radiation dose reduction in chest CT:a review.AJR Am J Roentgenol,2008,190(2):335-343.
  • 6Zhu X,Yu J,Huang Z.Low-dose chest CT:optimizing radiation protection for patients.AJR Am J Roentgenol,2004,183(3):809-816.
  • 7Tack D,De Maertelaer V,Petit W,et al.Multi-detector row CT pulmonary angiography:comparison of standard-dose and simulated low-dose techniques.Radiology,2005,236(1):318-325.
  • 8McNitt-Gray MF.AAPM/RSNA Physics Tutorial for Residents:Topics in CT.Radiation dose in CT.Radiographics,2002,22(6):1541-1553.
  • 9Hamberg LM,Rhea JT,Hunter GJ,et al.Multi-detector row CT:radiation dose characteristics.Radiology,2003,226(3):762-772.
  • 10Kalva SP,Sahani DV,Hahn PF,et al.Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT:a phantom and human study.J Comput Assist Tomogr,2006,30(3):391-397.

共引文献94

同被引文献13

引证文献1

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部