摘要
采用高效液相色谱法,以乙腈+磷酸水溶液为流动相,使用SB—C_(18)为填料的不锈钢柱和紫外检测器,检测波长230 nm,对酰嘧磺隆和甲基碘磺隆钠盐进行定量分析。结果表明,酰嘧磺隆和甲基碘磺隆钠盐标准偏差为0.044、0.022,变异系数为0.87%、1.70%,平均回收率为99.2%、98.7%,线性相关系数为0.999 1、0.998 5。
A HPLC method was adopted for the separation and determination of amidosulfttron and iodosulfuron-methyl inmixed WDG formulation. The determination was carried out on SB-Ct8 column with acetonitrile and phosphoric acidwater as mobile phase and UV detector at 230 nm. The results showed that standard deviations of the method foramidosulfuron and iodosulfuron-methyl were 0.044, 0.022, the coefficients of variation was 0.87%,1.70%. the averagerecoveries were 99.2%, 98.7%, and the linear correlation coefficients were 0.999 1, 0.998 5, respectively.
作者
郭利丰
郑爱妹
徐永
丁佩
GUO Lifeng ZHENG Aimei XU Yong DING Pei(Institute for the Control ofAgrochemicals, Zhejiang Province, Hangzhou 310020, China)
出处
《世界农药》
CAS
2017年第2期52-54,共3页
World Pesticide