期刊文献+

Determination of PCDD/Fs and dioxin-like PCBs in food and feed using gas chromatography-triple quadrupole mass spectrometry 被引量:6

Determination of PCDD/Fs and dioxin-like PCBs in food and feed using gas chromatography-triple quadrupole mass spectrometry
原文传递
导出
摘要 A method was developed on a gas chromatograph coupled to a triple quadrupole mass spectrometer(GC-MS/MS) for trace level determination of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) and dioxin-like polychlorinated biphenyls(DL-PCBs) in food and feed. The results demonstrated good sensitivity and repeatability for PCDD/Fs and DL-PCBs at an extremely low level(10 pg mL^(-1) for 2,3,7,8-TCDD/F), as well as wide linear response of over 3 or 4 orders of magnitude in concentration ranges; 0.5–200 ng mL^(-1) for PeCDD/F and 0.2–2000 ng mL^(-1) for DL-PCBs. The method detection limits for PCDD/Fs and DL-PCBs were in the range from 0.018–0.17 pg g^(-1) to 0.13–0.36 pg g^(-1), respectively. The performance of the GC-MS/MS for food and feed sample analysis showed high precision and accuracy compared to the high resolution gas chromatograph/high resolution mass spectrometer. The results indicated the feasibility of GC-MS/MS as a confirmatory method for the measurement of PCDD/Fs and DL-PCBs in food and feed as required by European Union legislation. A method was developed on a gas chromatograph coupled to a triple quadrupole mass spectrometer (GC-MS/MS) for trace level determination of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) in food and feed. The results demonstrated good sensitivity and repeatability for PCDD/Fs and DL-PCBs at an extremely low level (10 pg mL-1 for 2,3,7,8-TCDD/F), as well as wide linear response of over 3 or 4 orders of magnitude in concentration ranges; 0.5-200 ng mL^-1 for PeCDD/F and 0.2-2000 ng mL^-1 for DL-PCBs. The method detection limits for PCDD/Fs and DL-PCBs were in the range from 0.018-0.17 pg g^-1 to 0.13-0.36 pg g^-1, respectively. The performance of the GC-MS/MS for food and feed sample analysis showed high precision and accuracy compared to the high resolution gas chromatograph/high resolution mass spectrometer. The results indicated the feasibility of GC-MS/MS as a confirmatory method for the measurement of PCDD/Fs and DL-PCBs in food and feed as required by European Union legislation.
出处 《Science China Chemistry》 SCIE EI CAS CSCD 2017年第5期670-677,共8页 中国科学(化学英文版)
基金 supported by the National Natural Science Foundation of China(21477156,21477155,41276195) Chinese Academy of Sciences(XDB14010100) the National Basic Research Program of China(2015CB453101)
关键词 PCDD/FS DL-PCBS FOOD FEED GC-MS/MS PCDD/Fs, DL-PCBs, food, feed, GC-MS/MS
  • 相关文献

同被引文献50

引证文献6

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部