摘要
通过查阅大量的文献资料,从热电偶、CO_2气体流量、恒温段、温度、自动控温系统中参数的设定、供气系统的严密性等方面,总结了焦炭反应性及反应后强度测定中应注意的问题,以期提高这两个指标测定结果的准确性。
Based on mass literature information,starting from aspects of thermocouple,CO2 airflow,constant temperature section,temperature,parameters determination of automatic temperature controlling system,and strict airing system,the article summarizes coke reactivity and post-reaction strength measurement matters,with a view to improve measurement accuracy of the above-mentioned two indexes.
出处
《山西建筑》
2016年第32期99-101,共3页
Shanxi Architecture
关键词
焦炭
热电偶
控温系统
供气系统
coke
thermocouple
temperature control system
airing system