期刊文献+

比较观察锁定钢板与AO钢板应用在肱骨近端骨折治疗中的临床疗效

Comparison of Locking Plate and AO Plate in Treatment of Proximal Humeral Fracture the Clinical Curative Effect
下载PDF
导出
摘要 目的对比分析锁定钢板与AO钢板应用在肱骨近端骨折治疗中的临床疗效。方法 66例以肱骨近端骨折患者为研究对象,随机分成两组。对照组采用AO钢板治疗,观察组采用锁定钢板治疗。结果治疗前,两组患者的Neer评分差异无统计学意义(P>0.05);治疗后,观察组患者的骨折愈合时间比对照组短,Neer评分比对照组高,并发症发生率(12.12%)比对照组低(3.03%),差异均具有统计学意义(P<0.05)。结论与AO钢板相比,锁定钢板在肱骨近端骨折治疗中的疗效显著。 Objective To analysis locking plate with AO plate used in the clinical curative effect in treatment of proximal humeral fractures.Methods 66 patients with proximal humeral fractures as the research object, and randomly divided into 2 groups. The control group treated with AO plate, the observation group was treated with locking plate. Results Neer score difference before treatment, 2 groups of patients have no statistical significance (P〉0.05);After treatment,the observation group of patients with fracture healing time, shorter than control group, Neer scores higher than the control group, low complication rate (12.12%) than the control group (3.03%),the differences were statistically significant (P〈0.05). Conclusion Compared with AO plate,locking plate in the treatment of proximal humeral fractures in the curative effect is distinct, have a higher clinical value.
出处 《中国继续医学教育》 2017年第8期134-135,共2页 China Continuing Medical Education
关键词 锁定钢板 AO钢板 肱骨近端 骨折 疗效 locking plate AO plate proximal humeral fracture curative effect
  • 相关文献

参考文献8

二级参考文献47

  • 1玉山江·阿布都克里木.肱骨近端加压锁定钢板与传统钢板治疗肱骨近端骨折的临床疗效比较[J].医学信息(医学与计算机应用),2016,29(27):243-244. 被引量:3
  • 2Matassi F,Angeloni R,Carulli C,et al.Locking plate and fibularallograft augmentation in unstable fractures of proximal humerus[J].Injury,2012,43(11):1939-1942.
  • 3Jo MJ,Gardner MJ.Proximal humerus fractures[J].Curr Rev Mus-culoskelet Med,2012,5(3):192-198.
  • 4Sproul RC,Iyengar JJ,Devcic Z,et al.A systematic review of lockingplate fixation of proximal humerus fractures[J].Injury,2011,42(4):408-413.
  • 5Burke NG,Kennedy J,Green C,et al.Locking plate fixation forproximal humerus fractures[J].Orthopedics,2012,35(2):250-254.
  • 6Kim SH,Lee YH,Chung SW,et al.Outcomes for four-part proximalhumerus fractures treated with a locking compression plate andan autologous iliac bone impaction graft[J].Injury,2012,43(10):1724-1731.
  • 7Aksu N,Karaca S,Kara AN,et al.Minimally invasive plate osteos-ynthesis(MIPO)in diaphyseal humerus and proximal humerusfractures[J].Acta Orthop Traumatol Turc,2012,46(3):154-160.
  • 8Ruchholtz S,Hauk C,Lewan U,et al.Minimally invasive polyaxiallocking plate fixation of proximal humeral fractures:a prospectivestudy[J].J Trauma,2011,71(6):1737-1744.
  • 9Yang H,Li Z,Zhou F,et al.A prospective clinical study of proximalhumerus fractures treated with a locking proximal humerus plate[J].J Orthop Trauma,2011,25(1):11-17.
  • 10沈是铭,毛宾尧,王毳,黄涛,贾学文,高林山,陈永坚.人工肱骨头置换治疗肱骨近端4部分骨折及骨折脱位[J].中国骨伤,2008,21(5):387-389. 被引量:5

共引文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部