期刊文献+

皮肤位移对人手运动图像三维检测精度的影响

Effect of skin movement on the measurement accuracy of human hand 3-D motion
原文传递
导出
摘要 为研究皮肤位移对人手运动三维图像检测精度的影响 ,对食指 -拇指对捏运动过程进行了测试、分析。并在此基础上 ,利用人手运动三维图像实时检测装置 ,进行了标定实验 ,取得了较为理想的测量效果。分析表明 :1)在进行手指一般运动分析时 ,如果在手指上选择优化的标志点粘贴位置 ,标志点族的面积和长度相对变化量小于 5 % ,皮肤位移产生的影响基本可以忽略不计 ;2 )皮肤位移对各指节测量精度影响有所不同 ,远侧指节误差较小 ,近侧指节产生的误差较大 ;3)当对捏指的屈曲角度增大 ,对捏运动周期百分比达 6 0 %时 ,皮肤位移对检测精度的影响快速增大。 The influence of skin movement on the accuracy of 3-D measurements was studied by experimentally analyzing pinching of the index finger and the thumb. The results were used to develop a 3-D hand motion analysis system. Tests show that, 1) the relative deformation of the area and length of surface markers on the finger is less than 5%, when the optimal marker configuration for each segment is used, so the effect of skin movement on the analysis of finger motion can be negligible. 2) The skin motion has different effect in the measurement accuracy for different joints. Relatively larges errors accuse with the metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints, with small errors for the distal interphalangeal (DIP) joint. 3) The errors strongly correlate with the finger pinching motion, especially when the pinching cycle percentage reaches 60%.
出处 《清华大学学报(自然科学版)》 EI CAS CSCD 北大核心 2002年第8期1061-1063,1067,共4页 Journal of Tsinghua University(Science and Technology)
基金 国家自然科学基金项目 (5 990 5 0 15 ) 科技部重点攻关项目 (96-92 0 -2 0 -14 ) 重庆大学机械传动国家重点实验室访问学者基金项目
关键词 人手三维运动检测 标志点 皮肤位移 对捏运动 误差分析 human hand 3-D motion measurement surface marker skin movement pinch motion error analysis
  • 相关文献

参考文献6

  • 1[1]Chèze L, Fregly B J, Diment J. A solidification procedure to faci litate kinematic analyses based in viaeo system data [J]. J Biomechanics, 1995, 28(7): 879-884.
  • 2[2]Soderkvist I, Wedin P. Determing the movements of the skeleto n usin g well-configured markers [J]. J Biomechanics, 1993, 26(1 2): 1473-1477.
  • 3[3]Schmidt R, Disselhorst-Klug C. A marker-based measurement prod u re for unconstrained wrist and elbow motions [J]. J Biomechanics, 1999, 32: 615-621.
  • 4[4]Manal K, McClay I. Comparison of surface mounted markers and attach ment methods in estimating tibial rotations during walking :an in vivo study [J ]. Gait and Posture, 2000, 11: 38-45.
  • 5[5]Cappozzo A, Cappello A. Surface-Marker cluster design criteria for 3-D bone movement reconstruction [J]. IEEE Eng Med Biol, 1997, 4 4(12): 66-88.
  • 6[6]Lucchetti L, Cappozzo A. Skin movement artefact assement and compen sation in the estimation of knee-joint kinematics [J]. J of Biomechan ics 1998, 31: 977-984.[7]Andriacchi T P, Alexander E J. A point cluster method for in vivo m otion analysis: applied to a study of knee kinematics [J]. J Biomechanical E ngi, 1998, 120: 743-788.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部