摘要
结合工程项目实际情况,对物流仓库的消防给水系统的设计参数选取和计算过程进行详细介绍,尤其是室内消火栓设计流量的折减计算,消防水泵的扬程计算,消防水池和高位消防水箱的有效容积计算,消火栓系统和自动喷水灭火系统的稳压泵设计压力确定和气压罐有效容积计算。
Based on logistics warehouse projects, an introduction to the selection and calculation process of the design parameters for fire-protection water supply system is made in detail, which includes the reduction factor of the design flow rate of indoor fire-hydrant, the pump head of fire-fighting pumps, valid volume of fire-fighting water basin and overhead fire-fighting water tank, the design pressure of stabilizing pump and valid volume of air pressure tank adopted in the fire hydrant system and sprinkler system.
作者
姚月姣
Yao Yuejiao(CCCC First Harbor Consultants Co., Ltd., Tianjin 300222, Chin)
出处
《港工技术》
2017年第2期64-66,共3页
Port Engineering Technology
关键词
物流仓库
消火栓
早期抑制快速响应喷头
稳压泵
气压罐
logistics warehouse
fire hydrant
early-suppression fast response sprinkler
stabilizing pump
air pressure tank