摘要 水位控制系统性能的优劣,对提高电厂功率机组的效率和延长使用寿命具有重要作用,若系统没有得到定期维护会造成重大的经济损失。带遗忘因子的最小方差算法是基于过程数据的性能评估方法,其评估结果具有实时性,为控制系统的维护提供了可靠依据。通过对海丰电厂火电机组低加水位控制回路进行的性能评估,验证了算法的时变有效性。 The performance of water level control system plays an important role in improving the efficiency and prolonging the service life of the power plant. If the system is not maintained regularly, huge economic losses may resuit. The least variance algorithm with forgetting factor is a performance assessment method based on process data, and the result of the evaluation is real - time, which provides a reliable basis for the maintenance of the control system. The performance assessment of the low water level control loop of thermal power units in Haifeng power plant is carried out, which verifies the time varying effectiveness of the algorithm.
作者 刘阳 王亚刚
出处 《电子科技》 2017年第5期40-42,共3页 Electronic Science and Technology
关键词 控制系统性能评估 最小方差 AR模型 水位控制 遗忘因子 control loop performance assessment minimum variance auto regressive model water level control forgetting factor
  • 相关文献

参考文献4

二级参考文献60

  • 1桂小阳,胡伟,刘锋,梅生伟.基于水轮发电机综合非线性模型的调速器控制[J].电力系统自动化,2005,29(15):18-22. 被引量:24
  • 2桂小阳,梅生伟,卢强.多机系统水轮机调速器鲁棒非线性协调控制[J].电力系统自动化,2006,30(3):29-33. 被引量:14
  • 3桂小阳,梅生伟,刘锋,卢强.水轮机调速系统的非线性自适应控制[J].中国电机工程学报,2006,26(8):66-71. 被引量:45
  • 4朱方,赵红光,刘增煌,寇惠珍.大区电网互联对电力系统动态稳定性的影响[J].中国电机工程学报,2007,27(1):1-7. 被引量:293
  • 5Harris T J.Assessment of control loop performance[J].Canadian Journal of Chemical Engineering,1989,67 (5):856-861.
  • 6De Vries W R,Wu S.Evaluation of process control effectiveness and diagnosis of variation in paper basis weight via multivariate time series analysis[J].IEEE Transactions on Automatic Control,1978,23 (4):702-708.
  • 7Grimble M J.Controller performance benchmarking and tuning using generalized minimum variance control[J].Automatic,2002,38 (12):2111-2119.
  • 8Huang B.A pragmatic approach towards assessment of control loop performance[J].International Journal of Adaptive Control and Signal Processing,2003,17 (729):589-608.
  • 9J.P.Gerry.Prioritizing and optimizing problem loops using a loop monitoring[J].In proceedings of the ISA,2002.
  • 10Kerezsi,J.Computer simulation of an industrial ethane-cracking furnace operation[J].IEEE Energy (IYCE),2013,66(4):1-5.