摘要
智能电网用户端电能管理系统及相关系统的运行关系到用户是否可以实时的采集相关用电数据和相关用电安全事宜,故针对用户端电能管理系统相关设备的不间断供电是一项值得深究和研讨。此文主要描述在用户端电能管理系统中UPS配置方案的。为保证通信设备在主电源中断或发生波动情况下,各系统设备仍能可靠地工作,各交流用电通信设备由交流配电柜或UPS电源提供交流电源,UPS配备蓄电池组,在停电时,蓄电池组为各系统提供所需备用电源。
Smart grid AMI system operation is related to whether the user can real-time collect the electricity data, uninterrupted power supply for the AMI related equipment is a problem worth studying and research, this paper mainly describes the system in the AMI UPS configuration scheme. In order to ensure the communication equipment in the main power supply interruption or fluctuation condition, the system equipment still can work reliably, the AC electric communication equipment by AC power distribution cabinet or UPS power supply AC power UPS with battery, during a power outage, the battery to provide backup power for the system.
出处
《中国仪器仪表》
2017年第5期51-55,共5页
China Instrumentation