摘要
对某型斯特林制冷机的膨胀机弹簧断裂原因进行分析,发现导致某型分置式斯特林制冷机膨胀机弹簧断裂的原因主要是所采用的弹簧材料内部存在较多的I元素和Cl元素夹杂,根据故障分析结论提出了相关预防措施,可以有效控制该类现象的再次发生。
The spring fracture reason of the expander in a Stirling cryocooler was analyzed. It was found that this was why there were much more chemical elements of I and CI in spring material. Some measurements were proposed to prevent spring fracture happen again.
出处
《低温与超导》
北大核心
2017年第5期11-14,49,共5页
Cryogenics and Superconductivity
关键词
斯特林制冷机
弹簧
失效分析
预防措施
Stirling cryocooler, Spring, Failure analysis, Prevenive measurements