期刊文献+

压水堆棒控系统动力熔断器烧毁原因分析及维修策略改进 被引量:1

Cause Analysis of Power Fuse Burned in Pressurized Water Reactor Control Rod System and Improvement of Maintenance Strategy
下载PDF
导出
摘要 对某核电厂反应堆棒控系统动力熔断器烧毁事件进行根本原因分析。通过对反应堆棒控系统原理和熔断器所在电路的分析,结合熔断器熔断特性和可控硅导通与关断特性,实测数据验证动力熔断器烧毁根本原因是可控硅性能异常导致相邻两相电压短路,相间短路造成两相动力熔断器瞬间熔断。并给出反应堆棒控系统维修策略改进建议。 For a nuclear power plant reactor control rod system power fuse burned event root cause analysis. Through the analysis of system principle for the reactor control rod system and the power cabinet circuit, combined with fuses fusing characteristics and thyristor turn on and off characteristics, the actual measurement data shows that the root cause of fuse burned is the thyristor performance abnormal, abnormal performance of thyristor cause a short circuit between two adjacent phase voltage, resulting in fuses instantly burned. And gives the maintenance strategy recommendations for improvement the reactor control rod system.
出处 《核科学与工程》 CSCD 北大核心 2017年第2期189-198,共10页 Nuclear Science and Engineering
关键词 反应堆棒控系统 熔断器 可控硅 相间短路 根本原因 Reactor control rod system Fuse Thyristor Short circuit between two phasepower supply Root cause
  • 相关文献

同被引文献14

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部