摘要 以唐山某购物广场建筑为例,分析了该购物广场建筑空调系统的特点,调研了目前该购物广场空调区域的舒适性及空调系统的能耗现状,得知该购物广场空调舒适性较差、空调能耗所占比重较大,存在很大的节能潜力。进而从空调系统的设备选型、空调区域室内参数设定、空调系统的新排风的能量利用、空调系统的划分等几个角度,提出了对于购物广场类建筑空调系统的节能策略,为唐山地区购物广场类建筑空调系统的节能优化提供参考。 Taking an example of a shopping plaza in Tangshan, the characteristics of air conditioningsystem about the shopping plaza are analyzed, as well as the comfort and the present situation of energyconsumption of air conditioning system. It is concluded that the air conditioning comfort is poorer, airconditioning energy consumption accounts for a large proportion, and energy - saving potential istremendous. From aspects including the equipment selection, indoor parameters set, fresh air and exhaustair energy utilization, and air conditioning systems division, energy saving skills are proposed for the airconditioning system of the shopping plaza, providing reference to shopping plaza buildings in Tangshan.
作者 赵金秀
机构地区 唐山学院
出处 《建筑节能》 CAS 2017年第5期130-133,共4页 BUILDING ENERGY EFFICIENCY
基金 唐山市科技局项目(15110210a)
关键词 购物广场 空调能耗 节能策略 室内温度 变新风比系统 全热交换器 shopping plaza energy consumption of air conditioning system energy saving strategy indoor temperature system of fresh air ratio changing whole heat exchanger