摘要
利用液碱将固体氢氧化铝加热溶解,生成偏铝酸钠,通过添加缓冲液、掩蔽剂、络合剂和封闭剂等溶液,用锌盐返滴定来测试氧化铝,建立了稳定的制样和测量体系。该方法简捷、快速,分析结果较为准确,重现性良好,完全满足钛白粉行业质量监控的需要,结果令人满意。
In this paper, an alkali liquid is used to heat and dissolve solid aluminum hydroxide to form sodium metaluminate and a stable sampling and measurement system was established by adding buffer solution, masking agent, complexing agent, blocking agent, etc. and testing alumina through zinc salt retitrating. The method is simple and rapid, accurate results can be achieved with good reproducibility and the quality control requirements can be met for the titanium dioxide industry.
出处
《中国涂料》
CAS
2017年第4期71-73,共3页
China Coatings
关键词
钛白粉
氢氧化铝
氧化铝
测定方法
titanium dioxide, aluminum hydroxide, alumina, test methods