摘要 根管治疗约诊间疼痛是根管治疗过程中常见的并发症之一,由于在根管治疗过程中对根尖周组织造成的微生物、机械和化学刺激,引起根尖周组织的急性炎症,临床表现出局部组织疼痛和肿胀。随着科技发展,机用镍钛器械的大量使用,使降低患者诊疗过程中的约诊间疼痛成为可能。文章就根管治疗约诊间疼痛的发生机制和预防控制措施做一介绍。 Endodontic interappointment pain is one of the common complications of root canal therapy.It arises from microbial,mechanical and chemical stimuli to root apical tissue during the root canal treatment,which can cause acute inflammation of the root apical tissue,and the clinical manifestations are local pain and swelling.With the development of science and technology,a great many nickel-titanium rotary instruments are widely used,so that it is possible to reduce the endodontic interappointment pain in patients in the process of treatment.This paper introduced the research status of occurrence mechanism and preventive control approach during the treatment of the root canal therapy.
作者 郭世博 薛明
出处 《中国实用口腔科杂志》 CAS 2017年第4期198-201,共4页 Chinese Journal of Practical Stomatology
关键词 根管治疗术 约诊间疼痛 镍钛器械 root canal therapy endodontic interappointment pain nickel-titanium instruments
  • 相关文献

参考文献3

二级参考文献35

  • 1Yoshimine Y, Ono M, Akamine A. The shaping effects of three nickel-titanium rotary instruments in simulated S-shaped ca- nals [J]. J Endod,2005,31(5):373-375.
  • 2Peters OA, Peters CI, Schonenberger K, et al. ProTaper rotary root canal preparation : effects of canal anatomy on final shape an- alyzed by micro CT [J]. Int Endod J,2003,36(2) :86-92.
  • 3Bergmans L, Cleynenbreugel JV, Beullens M, et al. Progressive versus constant tapered shaft design using NiTi rotary instru- ments [Jl. Int Endod J,2003,36(4) :288-295.
  • 4Schafer E, Erler M, Dammaschke T. Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instru- ments. Part 2. Cleaning effectiveness and shaping ability in se- verely curved root canals of extracted teeth [J]. lnt Endod J, 2006,39(3) :203-212.
  • 5Burklein S, Hiller C, Huda M, et al. Shaping ability and cleaning effectiveness of Mtwo versus coated and uncoated Easy Shape instruments in severely curved root canals of extracted teeth [J]. Int Endod J, 2011,44(5) :447-457.
  • 6Parashos P, Gordon I, Messer HH. Factors influencing defects of rotary nickel titanium endodontic instruments after clinical use [J]. J Endod,2004,30(10) :722-725.
  • 7Gambarini G,Testarelli L,Galli M,et al. The effect of a new fin- ishing process on the torsional resistance of twisted nickel-tita- nium rotary instruments [J]. Minerva Stomatol, 2010, 59 (7-8) :401-406.
  • 8Gergi R, Rjeily JA, Sader J, et al. Comparison of canal transpor- tation and centering ability of twisted files, Pathfile-ProTaper system, and stainless steel hand K-files by using computed to- mography [ J ]. J Endod, 2010,36(5) : 904-907.
  • 9De-Deus G, Moreira EJ, Lopes HP, et al. Extended cyclic fa- tigue life of F2 ProTaper instruments used in reciprocating movement [J]. Int Endod J,2010,43(12) : 1063-1068.
  • 10Pedull6 E, Grande NM, Plotino G, et al. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 differ- ent nickel-titanium rotary instruments [J]. J Endod, 2013,39 (2) :258-261.