期刊文献+

Steady-migration retention characteristics of peptides under gradient elution: application towards a dynamic separation method for minor-adjustments of the retention of peptides in RPLC

Steady-migration retention characteristics of peptides under gradient elution: application towards a dynamic separation method for minor-adjustments of the retention of peptides in RPLC
原文传递
导出
摘要 Minor-adjustment of the retention of peptides, induced by varying the mobile phase flow-rate(MPF-R), is a new dynamic separation method for simultaneously and rapidly identifying and improving the selectivity of hidden and overlapping peptide peaks. It can also-stabilize the reverse elution order of some pair-peaks under gradient elution in reverse phase liquid chromatography. The retention characteristics of peptides under gradient elution in RPLC was firstly found to be dominated by two variables of the steady region(SR) and migration region(MR). The changes in peptide retention induced by varying the MPF-R can be attributed to changes in the rate of bond breaking of multiple molecular interactions of peptides from the SR and of the mass transfer of peptides from the stationary phase to the mobile phase in the MR. The two dynamic variables were also found to independently depend on the type of peptide. Desirable results were obtained using six standard oligopeptides and a real sample of trypsin-digested lysozyme.It is expected that the quality control of peptide drugs, high dispersion of peptide peaks in peptide mapping and "bottom-up MS"in proteomics will be improved by this method, even enabling peptide purification on a preparative scale in industry. Minor-adjustment of the retention of peptides, induced by varying the mobile phase flow-rate(MPF-R), is a new dynamic separation method for simultaneously and rapidly identifying and improving the selectivity of hidden and overlapping peptide peaks. It can also-stabilize the reverse elution order of some pair-peaks under gradient elution in reverse phase liquid chromatography. The retention characteristics of peptides under gradient elution in RPLC was firstly found to be dominated by two variables of the steady region(SR) and migration region(MR). The changes in peptide retention induced by varying the MPF-R can be attributed to changes in the rate of bond breaking of multiple molecular interactions of peptides from the SR and of the mass transfer of peptides from the stationary phase to the mobile phase in the MR. The two dynamic variables were also found to independently depend on the type of peptide. Desirable results were obtained using six standard oligopeptides and a real sample of trypsin-digested lysozyme.It is expected that the quality control of peptide drugs, high dispersion of peptide peaks in peptide mapping and "bottom-up MS"in proteomics will be improved by this method, even enabling peptide purification on a preparative scale in industry.
出处 《Science China Chemistry》 SCIE EI CAS CSCD 2017年第6期829-836,共8页 中国科学(化学英文版)
基金 supported by the Foundation of Provincial Key Laboratory of Modern Separation Science (12JS091, 13JS117, 14JS096)
关键词 steady-migration retention liquid chromatography PEPTIDES dynamic separation minor-adjustment of retention elution orders steady-migration retention liquid chromatography peptides dynamic separation minor-adjustment of retention elution orders
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部