摘要 目的:应用IOL Master观察可疑原发性房角关闭(primary angle closure suspect,PACS)患者的双眼对称性。方法:横断面观察性研究。纳入可疑PACS患者56例112眼,测量双眼眼轴长度(axial length,AL)、前房深度(anterior chamber depth,ACD)、角膜白到白距离(white to white,WTW Distance),并比较其差异;分析左右眼差值(△AL、△ACD和△WTW)与年龄、性别的相关性。结果:配对样本t检验结果显示,左右眼AL、ACD、WTW的差异均无统计学意义(P>0.05)。△AL、△ACD和△WTW与年龄、性别无明显相关性。结论:PACS患者ACD、WTW、AL具有双眼对称性,且该对称性不随年龄、性别而改变。 AIM: To observe the interocular symmetry of primary angle-closure suspects' (PACS) parameters using IOL Master. ~ METHODS: A cross- sectional observational study. Totally 112 eyes from 56 subjects were enrolled to detect the difference of the bilateral axial length (AL), anterior chamber depth (ACD) and white to white distance (WTW), and to evaluate the correlation between the interocular differences of AAL, AACD and AWTW and age, gender. RESULTS. All the parameters were analyzed by paired- samples t test and there were no significant interocular difference (P〉0.05). There was no relation of △AL,△ACD and Avv-r3N with age and gender. CONCLUSION, Interocular symmetry of parameters by IOL Master was observed in PACS, and we found that the symmetry would not be altered when the age and gender had changed.
作者 江媛 吴小娜
机构地区 浙江医院眼科
出处 《国际眼科杂志》 CAS 2017年第6期1153-1154,共2页 International Eye Science
关键词 IOL MASTER 可疑原发性房角关闭 双眼对称性 诊断 IOL Master primary angle - closuresuspects i nterocular symmetry diagnosis
  • 相关文献

参考文献2

二级参考文献22

  • 1Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound :biometry for intraocular lens calculation. Clin Experiment Ophthalmol. 2003 ; 31 (2) : 121 - 124.
  • 2Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry:intraobserver and interobserver reliability. J Cataract Refract Surg. 2001 ;27( 12): 1961-1968.
  • 3Bechmann M,Thiel MJ,Nenbauer AS,et al. Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic p~hymetry. Cornea. 2001 ;20( 1 ) :50-54.
  • 4Sheng H, Botljer CA, Bullimore MA. Ocular component measurement using the Zeiss IOLMaster. Optom Vis Sci. 2004 ; 81 ( 1 ) : 27-34.
  • 5Nemeth J, Fekete O, Pesztenlehrer N. Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation. J Cataract Refract Surg. 2003 ; 29( 1 ) : 85-88.
  • 6Findl O, Kriechbaum K, Sacu S, et al. Influence of operator experience on the performance of ultrasound biometry compared to optical biometry before cataract surgery. J Cataract Refract Surg. 2003;29 (10): 1950-1955.
  • 7Reddy AR, Pande MV, Finn P, et al. Comparative estimation of anterior chamber depth by ultrasonography,Orbscan II,and IOLMaster. J Cataract Refract Surg. 2004; 30(6 ) : 1268-1271.
  • 8Lain AK,Chan R,Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt. 2001 ; 21 ( 6 ) : 477-483.
  • 9Baikoff G,Jitsuo Jodai H, Bourgeon G. Measurement of the internal diameter and depth of the anterior chamber:IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg. 2005 ; 31(9): 1722-1728.
  • 10Norrby S. Multicenter biometry study of 1 pair of eyes. J Cataract Refract Surg. 2001 ;27( 10): 1656-1661.