分析补偿不平衡负载时对多电平补偿器所产生的影响,然后比较不同拓扑结构补偿不平衡负载的能力,最后总结哪种多电平拓扑结构更适合于STATCOM并探讨未来的研究方向,为业内学者能更好开展多电平补偿器综合补偿的相关研究提供参考。
Firstly, the impact on muhi-level compensator under the unbalanced load is analyzed, then the performances of compensating unbalanced load for different topologiesare is compared. Finally, the multi-level topology and its future research direction of STATCOM are summarized, which can provide reference for the scholars to carry out relevant research.
出处
《贵州电力技术》
2017年第4期87-92,共6页
Guizhou Electric Power Technology
关键词
不平衡负载
综合补偿
多电平补偿器
负序电流
不同拓扑结构
unbalanced load
comprehensive compensation
multi-level compensator
negative sequence current
different topologies