摘要
由于地球温室效应的影响,夏季室外气温不断升高导致空调设备夏季经常出现高压保护及工作电流偏大等问题,既造成能耗增加,又带来了设备运行安全隐患。为了降低中央空调夏季运行成本及安全运行。大楼采用空调室外风冷凝器上加装了(软)水喷雾装置的原理进行降温处理,既提高了制冷效率又降低了运行成本和设备安全隐患。
Because of the influence of the earth's greenhouse effect, the summer outdoor temperature rising leads to air conditioning in the summer often appear such problems as high voltage protection and the working current is larger, both cause increase of energy consumption, and the safe hidden trouble of equipment operation. In order to reduce the central air conditioning in the summer running cost and safe operation. Building using air conditioning by adding the (soft) on the wind outdoor condenser water spray cooling principle of processing, can not only improve the refrigeration efficiency and reduce the operation cost and equipment safety hidden trouble.
作者
刘勇
LIU Yong(Shanghai Zizhu Information Cyberport Co. ,Ltd , Shanghai 200241,China)
关键词
风冷中央空调
水雾冷却装置
节能改造
air cooled central air conditioning
water mist cooling device
energy saving reconstruction