摘要
基于医院洁净手术室的供电的重要性,文章介绍了两种洁净手术室的供配电方案,并分析其不同供电方式的优缺点,随后论述洁净手术室配电系统中断路器、导线的选择等相关事宜注意事项。
Based on the importance of hospital clean operating room power supply, this paper introduces two kinds of power supply scheme of clean operating room, and analyze its advantages and disadvantages of different power supply mode, then discusses the clean operating room power distribution system of circuit breaker, conductor choice concerning all matters needing attention.
出处
《福建建筑》
2017年第5期96-99,共4页
Fujian Architecture & Construction
关键词
洁净手术室
供电方案
导线选择
断路器选择
Clean Operating Room
Power supply scheme
Wire selection
Circuit - Breakers selection