期刊文献+

ATP生物荧光技术应用于软式内镜消毒质量检测的可行性研究 被引量:22

Study on feasibility of ATP bioluminescence technology applied to disinfection quality monitoring of flexible endoscope
下载PDF
导出
摘要 目的:研究腺嘌呤核苷三磷酸(ATP)生物荧光检测法应用于软式内镜消毒效果检测的可行性。方法:随机抽取2014年10月至2015年3月科室重复使用的软式内镜,应用ATP生物荧光检测法及细菌培养计量法2种不同的检测方法,对随机抽取的30例软式内镜消毒效果进行检测,收集分析数据并作平行比较。结果:软式内镜消毒质量ATP生物荧光检测结果合格率为93.3%,细菌培养计量法合格率为96.7%。软式内镜外表面2种方法检测值均在合格范围,活检孔端口和内镜管腔内污染相对较重;2种检测方法并不具有显著的相关性,但其检测结果具有高度一致性。结论:ATP生物荧光检测技术可作为一种快速方便的初筛方法,实现医用软式内镜现场、即时、日常监测,辅助细菌培养计量法监控软式内镜的消毒质量。 Objective To explore the feasibility of applying ATP bioluminescence technology to disinfection quality monitoring of the flexible endoscope. Methods Totally 30 flexible endoscopes used repeatedly from October 2014 to March 2015 were randomly selected, and had the disinfection quality monitored by ATP bioluminescence technology and bacterial culture method respectively. Parallel comparison was carried out to evaluate the feasibility of applying ATP bioluminescence technology to disinfection quality monitoring of the flexible endoscope. Results ATP bioluminescence technology showed that the qualification rate of the disinfection was 93.3%, and bacterial culture method found it was 96.7%. The two methods proved the outer surface of the endoscope had the disinfection acceptable while the biopsy hole and intracavity not. There was no significant correlation between the two methods while high consistency between the detection results by the two methods. Conclusion ATP bioluminescence technology can be used for preliminary screening in field, instant and daily monitoring of the medical flexible endoscope, which assists bacterial culture method in disinfection quality monitoring of the flexible endoscope. [Chinese Medical Equipment Journal, 2017,38 (5) : 107-109]
机构地区 解放军
出处 《医疗卫生装备》 CAS 2017年第5期107-109,共3页 Chinese Medical Equipment Journal
关键词 ATP生物荧光检测 软式内镜 细菌培养 消毒监测 消毒质量 ATP bioluminescence detection flexible endoscope bacterial culture disinfection monitoring disinfection quality
  • 相关文献

参考文献3

二级参考文献20

  • 1邢书霞,张流波.医疗器械清洗效果评价方法进展[J].中国护理管理,2007,7(2):78-80. 被引量:71
  • 2Spach DH,Silverstein FE,Stamm WE. Transmission of infection by gastrointestinal endoscopy and bronchoscopy[J].{H}ANNALS OF INTERNAL MEDICINE,1993,(2):117-128.
  • 3Nelson DB. Infectious disease complications of GI endoscopy.part Ⅱ,exogenous infections[J].{H}Gastrointestinal Endoscopy,2003,(6):695-711.
  • 4Kimmey MB,Bumett DA,Carr-Locke DL. Transmission of infection by gastrointestinal endoscopy[J].{H}Gastrointestinal Endoscopy,1993,(6):885-888.
  • 5Dorothea Hansen,Daniel Benner,Martin Hilgenhoner. ATP measurement as method to monitoring the quality of reprocessing flexible endoscopes[J].German Medial Science,2004,(4):1-5.
  • 6RUTALA W A, WEBER D J. ERCP Scopes: what can we do to prevent infections? [ J]. Infect Control Hosp Epidemiol, 2015, 36 (6): 643-648.
  • 7ZHANG X, KONG J, TANG P, et al. Current status of cleaning and disinfeetion for gastrointestinal endoscopy in China: A survey of 122 endoscopy units [J]. Dig Liver Dis, 2011,43 (4) : 305 - 308.
  • 8ASGE Technology Committee, KOMANDURI S, ABU D B K , et al. Technologies for monitoring the quality of endoscope reprocessing [J]. Gastrointest Endosc, 2014, 80 (3): 369- 373.
  • 9ALFA M J, FATIMA I, OISON N. Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels [J]. Am J Infect Control, 2013,41 (3) : 245 -248.
  • 10VENKATESWARANA K, HATYORI N, LADUC M T, et al. ATP as a biomarker of viablemicro organismsinclean - room facilities [J]. J Microbiol Methods, 2003 (52) : 367 -377.

共引文献31

同被引文献165

引证文献22

二级引证文献75

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部