数字化口腔修复(33)——不同扫描仪精度的三维分析 被引量:3

Digital restorative dentistry and prosthodontics(33)——Three dimensional analysis of the accuracy of different scanners
原文传递
导出
摘要 目的:利用三维模型分析法,比较5种扫描仪扫描全牙列的扫描精度。方法:用Metrotom 1500计算机断层扫描仪(computed tomography,CT)扫描标准上颌树脂牙列模型作为对照组。该模型经实验组5种扫描仪(in Eos X5、D810、Ceramill MAP400、Arctica Autoscan、Cerec~AC Omnican)分别扫描3次,获取5组数据。利用Geomagic软件,将实验组数据分别与对照组数据进行匹配,测量其三维距离(three dimensional distance,3DD)、体积变化率(the rate of the volume change,RVC)和三角网格数,并进行统计分析。结果:5组重叠模型的3-DD值中,in Eos X5组和D810组相当,Arctica Autoscan组和Ceramill MAP400组相当,差异均无统计学意义(P>0.05);Cerec~AC Omnican组的3-DD值最大,Arctica Autoscan组和Ceramill MAP400组次之,in Eos X5组和D810组最小,差异有统计学意义(P<0.05)。5组重叠模型的RVC值中,Arctica Autoscan组和Ceramill MAP400组相当,差异无统计学意义(P>0.05);Cerec~AC Omnican组最大,Arctica Autoscan组和Ceramill MAP400组次之,继而为D810组,in Eos X5组最小,差异有统计学意义(P<0.05)。三角网格数与精度无线性相关性(P>0.05)。结论:不同扫描仪的精度之间均有一定的差异;扫描全牙列时,口外扫描仪的精度高于口内扫描仪。 Objective:Utilizing three-dimensional(3D)model analysis to evaluate the accuracy of five dental scanners when scanning whole dentition. Methods:The 3 D model data was used as the control group by using the Metrotom 1500 CT to scan the standard maxillary resin dentition model. This model was then scanned three times with five scanners ( inEos )(5, D810, Ceramill MAP400, Arctica Autoscan, Cerec AC Omnican)that was the experimental group. The data of experimental group was superimposed with the data of control group by the Geomagic software. The three dimensional distance(3-DD), the rate of the volume change (RVC)and triangle mesh number were measured and compared. Results:Among the 3-DD of five scanners, inEos X5 was similar with D810, and Arctica Autoscan was also similar Creamill MAP400 ( P 〉 0.05 ). The value of Cerec AC Omnican was maximum,next it was Arctica Autoscan and Creamill MAP400 ,inEos X5 and D810 was the minimum ( P 〈 0.05 ). There was no statistically significant difference in the value of RCV between Arctica Autoscan and Creamill MAP400. The RVC of Cerec AC Omnican was maximum, next was the Arctica Autoscan and Creamill MAP400, followed by the D810, the inEos X5 was the minimum( P 〈 0.05 ). There was no linear correlation between triangle mesh number and the accuracy of scanner( P 〉 0.05 ). Conclusion : There are some differences in the accuracy of different scanners, when scanning the whole dentition, the accuracy of the extraoral scanner is better than the intraoral scanner.
出处 《临床口腔医学杂志》 2017年第5期306-309,共4页 Journal of Clinical Stomatology
关键词 扫描仪 精度 三维距离 体积变化率 Scanner Accuracy 3-DD Rate of volume change ( RVC )
  • 相关文献

参考文献2

二级参考文献29

  • 1M6rmann WH, Brandestini M, Lutz F. The Cerec system:computer- assisted preparation of direct inlays in one setting [J]. Quintessenee Int, 1987,38 (3) : 457-470.
  • 2Schepke U, Meijer HJA, Kerdijk W, et al. Digital venus analog com- plete-arch impressions for single-unit premolar implant crowns: Op- erating time and patient preference [J]. J Prosthet Dent,2015, 114 (3) : 403-406.e I.
  • 3Miyazaki T, Hotta Y,Kunii J,et al. A review of dental CAD ! CAM: Current status and future perspectives from 20 years of experience [J]. Dent Mater J, 2009, 28 (1),44-56.
  • 4Van Noort, R. The future of dental devices is digital [J]. Dent Mater, 2012, 28 (1), 3-12.
  • 5Yuzbasioglu E,Kurt H,Turunc R,et al. Comparison of digital and conventional impression techniques:evaluation of patients" percep- tion, treatment comfurt, effectiveness, and clinical outcomes Eli. BMC Oral Health, 2014, 14(1) : 10-15.
  • 6Christensen GJ. The state of fixed prosthodontics impressions:room for improvement ~J]. J Am Dent Assoc, 2005, 136 (3):343-346.
  • 7Patzelt SB, Emmanouilidi A,Stampf S,et al. Accuracy of full-arch scans using intraoral scanners [J]. J Clin Oral Invest, 2014a, 18 (6): 1687-1694.
  • 8Hack GD, Barns D, Depaola L. In vitro evaluation of the ITero digital impression system [J]. ADA Pro Pro Rev, 2011,6 (2):6-10.
  • 9Patzeh SB, Lamprinos C,Stampf S,et al. The time efficiency of in- traoral scanners: An in vitro comparative study [J]. J Am Dent As- soc, 2014b, 145 (6), 542-551.
  • 10Fasbinder DJ,Potieny DJ. Accuracy of ocelusal contacts for crowns with chairside CAD/CAM techniques [J]. lnt J Comput Dent, 2010, 13 (4) : 303-316.

共引文献26

同被引文献20

引证文献3

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部