期刊文献+

微创玻璃体切除手术中脉络膜上腔出血原因分析 被引量:2

Analysis of the causes of suprachoroidal hemorrhage during 23-gauge vitrectomy
原文传递
导出
摘要 目的分析23G无自闭阀玻璃体切除手术中出现脉络膜上腔出血(suprachoroidal hemorrhage, SCH)的原因以及相关危险因素。方法收集2012年7月至2016年7月玻璃体切除手术4981例(4981眼)的临床资料,回顾性分析SCH的原因及相关危险因素。结果23G无自闭阀玻璃体切除手术中发生SCH9例(9眼,0.18%),其中男6例、女3例,年龄30—75岁,平均(58.384-17.67)岁。与对照组(同期手术未发生SCH者)相比,SCH组患者在年龄、术前视网膜脱离范围以及术中出现眼压明显波动者3个方面差异有统计学意义(P=0.031,0.024,0.002)。结论年龄、视网膜脱离范围及术中出现眼压明显波动是23G无自闭阀玻璃体切除手术中发生SCH的危险因素。 Objective To analyze the cause and related risk factors of suprachoroidal hemorrhage (SCH) during 23-gauge vitrectomy without self closing valve. Methods Total of 4981 eyes of 4981 patients underwent vitrectomy from Jul. 2012 to Jul. 2016 were selected and analyzed retrospectively. The cause and related risk factors of SCH were analyzed. Results During 23-gauge vitrectomy without self closing valve, SCH occurred in 9 eyes of 9 cases (0.18%). Among them, 6 cases were male and 3 cases were female. The mean age was (58.38 + 17.67 ) years. There were significant diffenrence between SCH group and control group in age ( P = 0. 031 ), range of retinal detachment ( P = 0. 024 ) and intraocular pressure obvious fluctuations during vitrectomy ( P = 0. 002). Conclusion The risk factors of SCH during 23-gauge vitrectomy without self closing valve are age, range of retinal detachment and intraocular pressure abnormity.
出处 《中华眼外伤职业眼病杂志》 2017年第5期385-388,共4页 Chinese Journal of Ocular Trauma and Occupational Eye Disease
基金 武汉市卫生计生科研基金(WX16E03)基金项目:爱尔眼科医院集团科研基金(AFl601D3)
关键词 出血 脉络膜上腔 玻离体切除术 23 G 无自闭阀 因素 危险 Hemorrhage, suprachoroidal Vitrectomy, 23-gauge, without self closing valve Factors, risk
  • 相关文献

参考文献4

二级参考文献61

  • 1傅贤波.微创外科概念的新认识[J].中国微创外科杂志,2002,2(z1):42-44. 被引量:20
  • 2李双农,唐仕波,李加青,赖铭莹,白宁艳,高艺.25G经结膜无缝线玻璃体切除手术系统的初步临床应用效果[J].中华眼科杂志,2004,40(6):419-421. 被引量:19
  • 3Machemer R, Parel JM, Norton EW, et al. Vitrectomy : a pars plana approach. Trans Am Acad Ophthalmol Otolaryngol, 1971, 75 : 813-820.
  • 4O'Malley C, Heintz RM Sr. Vitrectomy with an alternative instrument system. Ann Ophthalmol, 1975, 7: 585-588, 591- 594.
  • 5de Juan E Jr, Hickingbotham D for vitreous surgery. Refinements in Am J Ophthalmol, 1990, 109: 218-220.
  • 6Fujii GY, De Juan E Jr, Humayun MS,et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology, 2002, 109 : 1814-1820.
  • 7Oshima Y, Wakabayashi T, Sato T, et al. A 27-GauGe instrument system for transconjunctival sutureless microincision vitrectomy surgery. Ophthalmology, 2010, 117: 93-102.
  • 8Eckardt C. Transconjunctival sutureless 23-Gauge vitrectomy. Retina, 2005, 25: 208-211.
  • 9Oliveira LB, Reis PA. Silicone oil tamponade in 23-Gauge transconjunctival sutureless vitrectomy. Retina, 2007, 27 : 1054- 1058.
  • 10Oshima Y, Chow DR, Awh CC, et al. Novel mercury vapor illuminator combined with a 27/29-gauge chandelier light fiber for vitreous surgery. Retina, 2008, 28:171-173.