期刊文献+

基于蓝牙芯片CC2541的计步器设计 被引量:2

Design of Pedometer Based on Bluetooth Chip CC2541
下载PDF
导出
摘要 为了实现穿戴式计步器准确计算步伐,本论文设计了一种基于蓝牙芯片CC2541和六轴传感器MPU6050的电子计步器系统。在开发过程中,自主设计了一个简易的电子计步器系统开发板,实现了运动姿态的检测,加速度数据处理和步数在蓝牙设备终端显示。实验结果表明:在走100步时,具有较可靠的稳定性及准确性。该电子计步器可设计为15mm×15mm的小体积仪器,且结构简单、功耗低、抗振动冲击能力强,能够满足较高精度的计步测量要求。 In Order to realize accurate step-counting in wearable equipment, an electronic pedometer system is designed, which is mainly composed of a Bluetooth chip CC2541 and six-axis sensor MPU6050. A simply electronic pedometer system development kit is designed, which has the functions of motion detection, acceleration data processing and Bluetooth device terminal displaying. Experimental results indicate that the system is stability and accuracy when people take 100 steps. This system can be designed as 15mm× 15mm, which is small in size, simple in structure and consumes little power. It can satisfy the system requirements of stepcounting in precision.
出处 《电脑与电信》 2017年第5期69-72,共4页 Computer & Telecommunication
关键词 六轴传感器MPU6050 计步器 低通滤波器 合理阈值 高精度 six-axis sensor MPU6050 pedometer low-pass filter reasonable threshold high precision
  • 相关文献

参考文献6

二级参考文献47

  • 1宋浩然,廖文帅,赵一鸣.基于加速度传感器ADXL330的高精度计步器[J].传感技术学报,2006,19(4):1005-1008. 被引量:35
  • 2周兆丰,刘守印,侯向锋.步态加速度信号的无线采集系统设计[J].单片机与嵌入式系统应用,2007,7(5):57-60. 被引量:6
  • 3Murray M P, Drought A, Kory R C. Walking pattern of normal men [J]. The Journal of Bone and Joint Surgery, 1964, 46: 335-360.
  • 4Ailisto K, Lindholm M, Mantyjarvi J, et ah Identifying people from gait pattern with accelerometers [C]// Proceeding of SPIE, Biometric Technology for Human identification Ⅱ . Orlando, FL, United States, 2005 : 7 - 14.
  • 5Gafurov D, Snekkenes E, Pours P. Spoof attacks on gait authentication system [J]. IEEE Transactions on Information Forensics and Security, 2007, 2(3): 491-502.
  • 6LIU Rong, ZHOU Jianzhong, LIU Ming, et al. A wearable acceleration sensor system for gait recognition [C]// Proceeding of 2nd IEEE Conference on Industrial Electronics and Applications. Harbin, China, 2007 : 2654 - 2569.
  • 7Bernard A, Gilles B, Claude T, et al. Reference data for normal subjects obtained with an accelerometric device [J]. Gait and Posture, 2002, 16(2) : 124 - 134.
  • 8Michael W. Gait Analysis: An Introduction, Third Edition [M]. Great Britain: Reed Educational and Professional Publishing Ltd, 2002:51 - 56.
  • 9Deng P S, Liao H Y, Chin W H, et al. Wavelet-based off-line handwritten signature verification [J]. Computer Vision and Image Understanding, 1999, 76(3) : 173 - 190.
  • 10Avila C S, Reillo R S. Two different approaches for iris recognition using Garhor filter and muhiseale zero-crossing representation [J]. Pattern Recognition, 2005, 38(2): 231 - 240.

共引文献159

同被引文献22

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部