期刊文献+

某电梯钢丝绳断裂失效分析 被引量:3

Failure Analysis on Fracture of Steel Wire Ropes of an Elevator
下载PDF
导出
摘要 某小区电梯在空载运行时钢丝绳发生断裂,导致电梯突然停止运行。通过现场勘查、宏观观察、化学成分分析、破断拉伸试验、扫描电镜分析的方法,对钢丝绳的断裂原因进行了分析。结果表明:钢丝绳起裂源位于钢丝心部,断裂性质为一次性韧性断裂,断裂是由单根钢丝绳过载造成的。 The steel wire ropes of the elevator in a housing estate fractured during no-load operation,which led to a sudden stop running of the elevator.Through the site investigation,macroscopic observation,chemical composition analysis,breaking tensile testing and scanning electron microscope analysis,the fracture reasons of steel wire ropes were analyzed.The results show that:the crack source of the steel wire rope was located in the core of the steel wire rope;the fracture mechanism was one-time ductile fracture;the fracture was caused by the overload of single steel wire rope.
作者 邱康勇 吴继权 丁二喜 QIU Kangyong WU Jiquan DING Erxi(Shenzhen Institute of Special Equipment Inspection and Test, Shenzhen 518029, China)
出处 《理化检验(物理分册)》 CAS 2017年第5期375-377,共3页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 电梯 钢丝绳 韧性断裂 过载 elevator steel wire rope ductile fracture overload
  • 相关文献

同被引文献20

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部