摘要 停(备)用保养是经常被基建电厂忽略的一个重要环节。通过自身长期参与基建电厂调试经验,发现长期连续运行的热力系统腐蚀情况要好于经常停(备)用机组的腐蚀情况。文中介绍了缓(停)建基建电厂停(备)用保养方法,同时对保养方法效果进行评价,说明根据基建电厂缓(停)建类型及停工时间长短,选用相适应的保养方法,可以有效地减缓热力系统、汽轮机和空冷岛等设备的金属腐蚀,值得推广应用。 Based on my own experiences of participating in the commissioning of infrastructure power plants, I realized that the corrosion of the continuously operating thermodynamic system is lower than that of units often under lay-up maintenance.Based on the on-site situations, the half shutdown can be divided into two different types:the stopped (suspended) project after boiler hydrostatic test or the stopped(suspended) project after turbine latched and rolled. The stopped (suspended) project is indefinite with a long period, and it is difficult to be maintained without any supervision. This paper introduced the method of maintenance and maintenance of the construction of the power plant, and then evaluated the effect of the maintenance method. It showed that according to the type of the construction and the downtime of the infrastructure power plant, the appropriate maintenance method can be used to reduce the heat systems, steam turbines and air-cooled islands and other equipment metal corrosion.h is worth promoting the application.
作者 袁选民 高建成 冯荣彬 YUAN Xuanmin GAO Jiancheng FENG Rongbin(Northwest China Electric Power Test Research Institute,Xi' an, Shaanxi 710032, China)
出处 《清洗世界》 CAS 2017年第5期22-25,43,共5页 Cleaning World
关键词 缓(停)建 停(备)用保养 热力系统 保养评价 stopped (suspended) project lay-up maintenance thermodynamic system maintenance evaluation
  • 相关文献

参考文献5

共引文献19

同被引文献37

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部