摘要
为了对分区分级双P型燃气辐射管喷口结构、位置进行优化,提高燃烧效率.首先对分区分级双P型燃气辐射管进行了实验和数值研究,结果发现,除NO_x体积分数的误差为11.6%外,其他参数的偏差都在1%以内,证明该模型具有可靠性.在此基础上,通过研究主管和支管的喷口位置及喷口结构等参数,进行了气体温度和壁面温度的研究分析.结果显示:随着主管喷口位置向外移动,分区分级燃气辐射管表面温度的最高值逐渐减小,壁面温度的最低值逐渐增大.支管喷口位于三通管与支管交线处时,可以减少高温气体对辐射管管壁的冲击作用,提高支管径向的温度均匀性,延长辐射管使用寿命;主管喷口的形式为完全预混式喷口时,壁面温差最小;支管喷口的形式为不对称式时,分区分级燃气辐射管壁面温差最小,燃烧热效率最高.
To optimize combustion efficiency, the structural characteristics of the zoned and staged double P-type gas-fired radiant tube were improved. The corresponding experimental and numerical studies were performed on the new radiant tube and the results show that deviations in the monitoring parameters are less than 1% , except for a NO concentration of 11.6% , which proves the reliability of the model. On this basis, the gas and wall temperatures were compared by changing the nozzle position and structure parameters of main and branch pipes. The results show that as the nozzle position moves outward, the highest value of the surface temperature of the radiant tube gradually decreases and the minimum value of the wall temperature gradually increases. When the nozzle of the branch pipe locates at the intersection of the tee and branch pipes, it helps to reduce the impact of the high temperature gas on the pipe wall, improve the uniformity of the branch radial temperature, and prolong the service life of the radiation tube. When the nozzle is fully premixed, the temperature difference is minimized. When the pipe nozzle is asymmetric, the difference in the wall temperatures is minimized and the thermal combustion efficiency is the highest.
作者
徐钱
冯俊小
周闻华
陈艳梅
XU Qian FENG Jun-xiao ZHOU Wen-hua CHEN Yan-mei(School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China)
出处
《工程科学学报》
EI
CSCD
北大核心
2017年第5期756-761,共6页
Chinese Journal of Engineering
基金
"十三五"国家重点科技支撑计划资助项目(2016YFB0601300)
关键词
辐射管
喷嘴
空燃比
结构
氮氧化物控制
radiant tube
nozzle
air-fuel ratio
structure
nitrogen oxide control