期刊文献+

PVA纤维对混凝土抗裂性能的影响研究 被引量:3

Research on Effect of PVA Fiber to Concrete Anti-cracking Performance
下载PDF
导出
摘要 针对锦屏二级水电站引水隧洞末端的4个调压井,通过掺入不同掺量的PVA纤维进行混凝土的开裂性能试验研究,得出PVA混凝土最佳纤维掺量为0.9%的结果。在此基础上,探讨了PVA纤维混凝土的配合比,提出了施工现场泵送适应性建议。 Aiming at the four surge shafts of Jinping II hydropower station diversion tunnel, by mixing different mixing amount PVA fiber to research concrete cracking performance test, it gets the best PVA concrete fiber mixing amount is 0.9%. Based on the result, it discusses the mixing proportion of PVA fiber concrete and puts forwards the adaptation advice of construction site pumping.
作者 张涛 牛贺洋 Zhang Tao Niu Heyang(Yellow River Conservancy Technical institute, Kaifeng 475004, Henan, Chin)
出处 《黄河水利职业技术学院学报》 2017年第2期29-31,共3页 Journal of Yellow River Conservancy Technical Institute
基金 2015年黄河水利职业技术学院科研基金项目:PVA纤维对混凝土抗裂性能影响的研究(2015QNKY004)
关键词 PVA纤维 抗裂性能 配合比 掺量 和易性 PVA fiber anti-cracking performance mixing proportion mixing amount mixability
  • 相关文献

参考文献2

二级参考文献12

  • 1王卫中,冯忠绪.二次搅拌工艺对混凝土性能影响的试验研究[J].混凝土,2006(4):40-42. 被引量:34
  • 2高淑玲,徐世烺.PVA纤维增强水泥基复合材料拉伸特性试验研究[J].大连理工大学学报,2007,47(2):233-239. 被引量:87
  • 3LI V C. Advances in ECC research[A]. ACI Special Publication on Concrete: Material Science to Applications(SP 206-23)[C]. [sl] : ACI, 2002 : 373-400.
  • 4ZHANG J,LI V C, ANDRZEJ S N, et al. Introducing ductile strip for durability enhancement of concrete slabs[J]. Journal of Materials in Civil Engineering,2002,14(3) : 253-261.
  • 5ZHANG J, LI V C. Monotonic and fatigue performance of engineered fiber reinforced cementitious composite in overlay system[J]. Cement and Concrete Research, 2002,32 (3) : 415-423.
  • 6LI V C. From mieromechanics to structural engineering-The design of eementitous composites for civil engineering applications[J]. JSCE J of Struc Mechanics and Earthquake Engineering, 1993,10(2) :37-48.
  • 7LI V C, WU C, WANG S, et al. Interface tailoring for strainhardening PVA-ECC[J]. ACI Materials Journal, 2002,99 ( 5 ) :463-472.
  • 8中华人民共和国建设部、国家质量监督检验检疫总局.GB/T50081-2002,《普通混凝土力学性能试验方法标准》[S].北京:中国建筑工业出版社,2002.
  • 9.中国工程建设标准化协会标准:《普通混凝土力学性能试验方法标准》CECS13:89[S].北京:中国计划出版社,1989..
  • 10ASTM C1018-97, Standard test method for flexural toughness and first crack strength of fiber reinforced Concrete (Using Beam With Third-Point Loading), Book of ASTM Standard.1998.