期刊文献+

移动医疗器械终端产品质控技术研究 被引量:4

Study on the Quality Control Technology of the Terminal Products of Mobile Medical Device
下载PDF
导出
摘要 移动医疗器械是有源医疗器械与移动互联网技术深度融合的产物,是医疗器械异军突起的新方向,是助推移动医疗服务、构建医疗健康大数据体系的重要基础。移动医疗器械的有效性和安全性的评价存在很多新的问题和挑战。如何解决这些质控技术问题,关系到新产品能否快速注册上市。本文讨论了目前移动医疗器械质控领域面临的几个突出的技术问题,包括反射式血氧、无创血糖、手机光辐射、柔性电池、柔性传感器等,对监管部门加强相关领域的质控工作给出了建议。 Mobile medical device originates from the integration between active medical device and mobile internet, and becomes a blooming branch of medical device industry. It is important basis to promote mobile health and construct medical big data system. The evaluation of effectiveness and safety of terminal products of mobile medical device is facing various challenges, which affects the registration period of these products. In this paper, several important technical issues on the testing of mobile medical device were discussed, including reflective oximetry, noninvasive glucose monitor, mobile optical radiation, fexible batteries and fexible sensors. Advice for corresponding departments to enhance related quality control was proposed.
出处 《中国医疗设备》 2017年第6期9-11,19,共4页 China Medical Devices
基金 中国食品药品检定研究院中青年基金项目(2015C02) 中国药品监督管理研究会课题"移动医疗发展趋势与监管政策研究"
关键词 移动医疗器械 质量控制 反射式血氧 无创血糖 柔性材料 mobile medical device quality control refective oximetry noninvasive glucose monitor fexible material
  • 相关文献

参考文献3

二级参考文献29

  • 1KLONOFF D C.Noninvasive blood glucose monitoring[J].Diabetes Care,1997,20(3):433-437.
  • 2TENHUNEN J,KOPOLA H,MYLLYLA R.Non-invasive glucose measurement based on selective near infrared absorption:requirements on instrumentation and spectral range[J].Measurement,1998,24:173-177.
  • 3WAYNANT R W,CHENAULT V M.Overview of non-invasive fluid glucose measurement using optical techniques to maintain glucose control in diabetes mellitus[J].IEEE Lasers Electro-optics Soc Newsletters,1998,12:3-6.
  • 4BURMEISTER J J,ARNOLD M A,SMALL G W.Spectroscopic considerations for noninvasive blood glucose measurements with near infrared spectroscopy[J].IEEE Lasers Electro-optics Soc Newsletters,1998,12:7-8.
  • 5MALIN S F.Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy[J].Clin.Chemistry,1999,45:1651-1658.
  • 6KLONOFF D C,BRAIG J,STERLING B,TREBINO R.Mid-infrared spectroscopy for noninvasive blood glucose monitoring[J].IEEE Lasers Electro-optics Soc Newsletters,1998,12:13-14.
  • 7ENEJDER A M K.Raman spectroscopy for noninvasive glucose measurements[J].Journal of Biomedical Optics,2005,10(3):031114-1-9.
  • 8MACKENZIE H A.Advances in photoacoustic noninvasive glucose testing[J].Clin.Chem.,1999,45(9):1587-1595.
  • 9CAMERON B D,GORDE H,COTE G L.Development of an optical polarimeter for in vivo glucose monitoring[J].Proceedings of SPIE,1999,3599:43-49.
  • 10CHO O K,KIM Y O,MITSUMAKI H,et al.Noninvasive measurement of glucose by metabolic heat conformation method[J].Clinical Chemistry,2004,50(10):1894-1898.

共引文献34

同被引文献42

引证文献4

二级引证文献17