摘要 在HL-2A装置上采用石英晶体微天平(QCM)测量碳元素及其化合物的沉积质量,从测量的数据可知,每次等离子体放电后QCM的沉积量都会有细微变化,每次放电测得的沉积质量约为0.1~10μg。沉积量的变化与沉积物质再腐蚀或者溅射有关。根据一天的测量结果,可以计算得出HL-2A装置偏滤器区域平均每次放电(非H模放电)的沉积厚度约为10nm。 A set of quartz crystal microbalance (QCM) was installed in HL-2A tokamak to measure me material deposition of carbon and its compounds. In the experiments, the mass deposited in each shot is usually in the magnitude of 0.1-10μg, an increase or decrease of the mass deposited could be induced by re-erosion and sputtering, which needs further investigation. The results also indicate that more mass can be deposited on the QCM after disruption. In addition, the average thickness of deposited layer in each shot is estimated to be 10nm in HL-2A tokamak.
出处 《核聚变与等离子体物理》 CSCD 北大核心 2017年第2期144-151,共8页 Nuclear Fusion and Plasma Physics
基金 国家磁约束核聚变能发展研究专项(2015GB106001) 四川省科技厅国际合作重点项目(2016HH0006)
关键词 石英晶体微天平 沉积 HL-2A装置 偏滤器 等离子体与材料的相互作用 Quartz crystal microbalance Deposition HL-2A tokamak Divertor Plasma material interaction
  • 相关文献

参考文献1

二级参考文献25

  • 1谢乃贤,朱天平.一种简易的电化学石英晶体微天平自动记录电路[J].分析仪器,1995(4):29-31. 被引量:2
  • 2G. Sauerbrey. The use of quartz oscillators for weighing thin layers and for microweighing[J]. Z. Phys., 1959, 155: 206- 212.
  • 3S. Bruckenstein, S. Swathirajan. Potential dependence of lead and silver underpotential coverages in acetonitrile using a piezoelectric crystal oscillator[J]. Electrochim Acta, 1985, 30: 851-855.
  • 4W. Henry, R. Raymond. Surface acoustic wave probe for chemical analysis, 1. Introduction and instrument description[J]. Anal. Chem., 1979, 51(9): 1458-1564.
  • 5G. A. Guilbauit, in C. Lu, W. Czanderna(eds.). Application of piezoelectric quartz microbalance[M], New York: Elesevier, 1984.
  • 6P. L. Konash, G. J. Bastiaans. Piezoelectric crystals as detectors in liquid chromatography[J]. Anal. Chem., 1980, 52(12): 1929-1931.
  • 7M. T. Gomes, T. A. Rocha, A. C. Duarte, J. P. Oliveira. Determination of sulfur dioxide in wine using a quartz crystal microbalance[J]. Anal. Chem. 1996, 68(9): 1561-1564.
  • 8T. Nomura, M. Iijima. Electrolytic determination of nanomolar concentrations of silver in solution with a piezoelectric quartz crystal[J]. Anal.Chim.Acta, 1981, 131:97-102.
  • 9T. Nomura, T.Nagamune. Internal electrolytic determination of silver in solution with a piezoelectric quartz crystal[J]. Anal. Chim. Acta. 1983,155: 231-234.
  • 10S. Bruckenstein, M. Shay. An in situ weighing study of the mechanism for the formation of the adsorbed oxygen monolayer at a gold electrode[J]. J. Electronal. Chem., 1985, 189(1): 131-136.

共引文献2

同被引文献5

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部