期刊文献+

华北某再生水管网余氯衰减分析及影响因素研究 被引量:1

Analysis of residual chlorine decay in a reclaimed water pipe network in North China and study on its influencing factors
下载PDF
导出
摘要 针对华北某市再生水管网余氯衰减趋势及变化规律展开研究。采用EPANET软件对该区域再生水管网余氯衰减进行了水力水质模拟,得到了该管网的余氯分布情况,并通过实际管网取样检测验证了模型模拟的精确度。对实际管网多个水质指标进行取样检测,分析了各指标对余氯衰减的影响。余氯在夏季衰减更剧烈,水温、管道浊度是余氯衰减的重要影响因素,管网p H值变化不大,其对余氯衰减的影响不大,TOC与余氯衰减的关系较复杂,余氯衰减速度和管网流速呈现正相关关系,且管壁对余氯衰减的作用不可忽视。 The research on residual chlorine decay tendency and change rules of a reclaimed water pipe network of a city located in North China were carried out. Using EPANET software to simulate the hydraulic power and water quality of residual chlorine decay in the reclaimed water pipe network of the said district, the distribution situation of residual chlorine was gotten, and the accuracy of the model simulation was verified through detecting the water samples taken from actual pipe network. Many quality indicators of water samples taken from actual pipe network were detected, and the effect of all those indicators on residual chlorine decay were analyzed. The residual chlorine decays faster in summer, water temperature and turbidity of pipeline were important influencing factors of residual chlorine decay. The pH value of pipe network changes little and has lit- tle effect on residual chlorine decay. The relationship between TOC and residual chlorine decay was complex; the residual chlorine decay rate had a positive correlation with pipe network flow rate and the effect of tube wall on residual chloride decay could not be ignored.
出处 《工业用水与废水》 CAS 2017年第3期10-14,共5页 Industrial Water & Wastewater
基金 国家自然科学基金项目(51478307)
关键词 再生水管网 余氯衰减 EPANET 影响因素 reclaimed water pipe network residual chloride decay EPANET influencing factors
  • 相关文献

参考文献8

二级参考文献63

  • 1孙建,赵晓颖,孙杰.供水管材对管网水质影响分析[J].城镇供水,2004(3):34-35. 被引量:1
  • 2童祯恭,刘遂庆.供水管网水质安全及其保障措施探讨[J].净水技术,2005,24(1):49-53. 被引量:24
  • 3赵洪宾.给水管道的余氯消耗规律的初步研究[J].给水排水,1986,12(6):11-15.
  • 4Grayman W M, Clark R M, Males R M. Modeling distribution-system water quality: dynamic approach. J. Water Resour. Ping. and Mgnt., 1988, 114:295--312.
  • 5Biswas P,Clark R M. A model for chlorine concentration decay in pipes. Wat. Res., 1993, 27:1715--1724.
  • 6Clark R M, Grayman W M, Goodrich J A. Measuring and modeling chlorine propagation in water distribution systems.J. Water Resour. Ping. and Mgnt. , 1994, 120:871--887.
  • 7Beatty R, Bliss P J, Vintage D C. Analysis of factors influencing chlorine decay in piped distribution systems. J.AWWA, 1996, 16:159--165.
  • 8James C Powell, Nicholas B Hallam, John R West. Factors which control bulk chlorine decay rates. Wat. Res., 1996,34( 1 ) : 117 -- 126.
  • 9Jadas Hecart A, EI Moher A, Stitou M. The chlorine demand of a treated water. Wat. Res. , 1992, 26:1073 --1084.
  • 10Dharmarajah H, Patania N. Empirical modeling of chlorine and chloramine residual decay. AWWA Proceedings: Water Quality for the New Decade. Annual Conference, Philadelphia, PA, 1991, (6):569--577.