摘要 探讨了FLUKE公司5520A型多功能校准器交流电流的溯源问题,介绍了两种不同的校准方法,即用高准确度数字多用表直接校准和使用A40B型交流分流器配合高准确度数字多用表进行校准。简单评定了两种校准方法对交流电流校准结果的不确定度,通过对比得到解决5520A型多功能校准器交流电流溯源的解决方案。对一个交流电流校准点的校准结果不确定度评定结果表明,所提出的解决方案能够满足5520A型多功能校准器交流电流的溯源要求。 The AC current traceability of 5520A multifunction calibrator manufactured by FLUKE company is discussed in the paper. Two different calibration methods are introduced, i.e. using a high precision digital multimeter only for direct calibration, and using A40B AC current shunt with a high precision digital multimeter for calibration. The uncertainties of AC current calibration results obtained by the two calibration methods are simply evaluated. By comparing the calibration uncertainties, a solution to AC current traceability of 5520A multifunction calibrator is presented. The uncertainty evaluation results of the calibration data acquired at a AC current calibration point show that the solution could meet the AC current traceability requirement of 5520A multifunction calibrator.
出处 《上海计量测试》 2017年第3期20-22,25,共4页 Shanghai Measurement and Testing
关键词 5520A型多功能校准器 交流电流 溯源 不确定度评定 5520A multifunction calibrator AC current traceability uncertainty evaluation
  • 相关文献

参考文献2

二级参考文献6

  • 1[1]JJG315-83,直流数字电压表检定规程[S].
  • 2国家质量监督检验检疫总局.测量不确定度评定与表示(JJFl059-2012).中国质检出版社,2012.
  • 3JJ6598-89直流数字电流表检定规程.
  • 4JJG724-91直流数字欧姆表检定规程.
  • 5JJG(航天)34-99交流数字电压表检定规程.
  • 6JJG(航天)35-99交流数字电流表检定规程.