摘要
采用平壁一维稳态传热模型对柳钢5号高炉炉役后期炉缸残余炭砖长度进行计算,计算结果与停炉后测量结果基本一致。停炉后采用碳复合砖对炉缸炉底进行大修,并配置了炉缸炉底侵蚀在线监控系统。总结高炉炉缸大修实践及其效果。
By adopting the plane wall one-dimensional steady-state conduction model to caculate the length of the residual carbon-bearing brick of No.5 Blast Furnace hearth in the post-campaign, the calculating results were basically the same as those measured after blowing-out. After shutting-down, the carbon-bearing brick was used to overhaul the hearth bottom and the on-line monitoring system for the hearth scouring was equipped. The overhaul practice of the blast furnace hearth and its effects were summarized.
关键词
高炉
炉缸
侵蚀诊断
碳复合砖
Blast Furnace
Hearth
Scouring Diagnosis
Carbon-bearing Brick