摘要 目的对比SPECT,探讨双源CT(DSCT)双能量心肌灌注成像的临床应用价值。方法搜集18例临床怀疑冠心痛或已知冠心病史的患者行双源CT双能量心肌灌注成像和静息/负荷心肌灌注锝-99mSPECT显像检查,并对其影像表现进行分析。结果 DSCT双能量心肌灌注成像检查1 8例患者,发现阳性1 4例,阴性4例。对比SPECT检查,14例DSCT阳性病例中,SPECT均发现了相同心肌部位的灌注缺损。而4例阴性病例中,SPECT检查有1例有心肌缺血。二者检出心肌灌注缺损的差异性无统计学意义(P>0.05)。结论DSCT双能量心肌灌注成像发现心肌灌注缺损的能力与SPECT大致相符,对冠心病的诊断有较大价值。 Objective To evaluate the clinical value of the nwocardial perfilsion imaging dual-source CT (DSCT) dual energy, in the comparison of SPECT. Methods 18 cases of clinically suspected or known coronary artel- disease were of collected. Then the patients underwent the myocardial perfusion imaging of DSCT and resting /loaded technetimn- 99m SPECT.The imaging findings then were analyzed further.Results In 18 patients with DSCT dual energy myocardial per(usion imaging, 14 cases were positive, when 4 cases were negative. Compared with SPECT examination, the same cardiac perfnsion defect of 14 positive cases were fimnd in SPECT as in DSCT. Among 4 negative cases of DSCT examination, loaded SPECT detected myocardial ischemia in I case. Detection rates of cardiac perfusion defect between DSCT with SPECT showed no significant difference(P〉0.05). Conclusion The myocardial perfusion imaging in DSCT dual energW possess the similar capability in myocardial perfusion defects with SPECT, and manifest great diagnosis value for coronary heart disease.
出处 《中国CT和MRI杂志》 2017年第7期66-68,共3页 Chinese Journal of CT and MRI
基金 珠海市科技计划立项项目(编号:2013114)
关键词 心肌灌注 第二代双源CT 体层摄影术 发射型电子计算机 单光子 Myocardial Perfusion The Second Generation dual-source CT Tomography, Emission-computed Single-photon
  • 相关文献

参考文献5

二级参考文献46

  • 1吕铁伟,田杰,江德勤,朱静.急性心肌梗塞动物模型的建立[J].中国比较医学杂志,2004,14(3):166-169. 被引量:14
  • 2朱海云,田建明,王莉,曾浩,黄胜东,徐训宇,陆健.MRI与正电子发射计算机体层、单光子发射计算机体层显像检测活性心肌的对比研究[J].中华放射学杂志,2005,39(6):593-598. 被引量:9
  • 3王晓樑,刘磊,梁峰,焦向英,郭永强,刘慧荣.大鼠在体心肌缺血/再灌注模型制备方法的改进[J].山西医科大学学报,2006,37(9):980-982. 被引量:11
  • 4Patel MR, Dehmer GJ, Hirshfeld JW, et al. ACCF/SCAI/STS/ AATS/AHA/ASNC 2009 Appropriateness Criteria for Coronary Revascularization: a report by the American College of Cardiology Foundation Appropriateness Criteria Task Force, Society for Cardiovascular Angiography and Interventions, Society of Thoracic Surgeons, American Association for Thoracic Surgery, American Heart Association, and the American Society of Nuclear Cardiology Endorsed by the American Society of Echocardiography, the Heart Failure Society of America, and the Society of Cardiovascular Computed Tomography. J Am Coll Cardiol,2009 ,53 :530-535.
  • 5Feuchtner G, Goetti R, Plass A, et al. Adenosine stress highpitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversiblemyocardial ischemia : comparison with magnetic resonance imaging. Circ Cardiovasc Imaging,2011, 4:540-549.
  • 6Crossett MP, Schneider-Kolsky M, Troupis J. Normal perfusion of the left ventricular myocardium using 320 MDCT. J Cardiovasc Comput Tomogr ,2011,5:406 -411.
  • 7Kaehenoura N, Gaspar T, Lodato JA, et al. Combined assessment of coronary anatomy and myocardial perfusion using multidetector computed tomography for the evaluation of coronary artery disease. Am J Cardiol, 2009, 103:1487-1494.
  • 8Mori S, Nishizawa K, Ohno M, et al. Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner. Br J Radiol,2006,79 : 888-892.
  • 9Tonino PA, De Bruyne B, Pijls NH, et al. Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med, 2009, 360:213-224.
  • 10Marcassa C, Bax JJ, Bengel F, et al. Clinical value, costeffectiveness, and safety of myocardial perfusion scintigraphy: a position statement. Eur Heart J, 2008, 29:557-563.