期刊文献+

降低1000 MW机组干除渣系统故障率的措施 被引量:1

The methods of decreasing the failure rate of dry deslagging system for a 1000 MW unit
下载PDF
导出
摘要 燃煤电站锅炉干除渣系统出现故障,会对锅炉的安全稳定运行产生影响。分析了某1 000 MW超超临界参数变压直流Π型锅炉干除渣系统故障停运的原因,提出了加强锅炉燃烧管控、调整锅炉吹灰方式、合理调整干除渣系统运行方式、加强干除渣系统参数调整等措施,有效降低了干除渣系统的故障率。 Once the dry deslagging system of coal-fired power plant boiler failed,it had a great influence on the safe and steady operation of boiler. This paper analyzed the failure reasons of dry deslagging system of parametric voltage transformation direct current Π-type boiler for a 1 000 MW ultra-supercritical unit,and proposed some measures to reduce the failure rate of dry deslagging system,such as strengthening combustion control,adjusting boiler soot blowing methods,adjusting the operation mode and strengthening the parameter adjustment of dry deslagging system,etc.
作者 杨杰 李洪泉
出处 《华电技术》 CAS 2017年第6期75-76,共2页 HUADIAN TECHNOLOGY
关键词 燃煤电站 Π型锅炉 干除渣系统 燃烧管控 吹灰 coal-fired power plant Π-type boiler dry deslagging system combustion control soot blowing