针对广州轨道交通信号系统使用ZYJ7电液转辙机及转换设备发生的3起典型故障进行分析,通过现场试验,找出了故障原因,并提出了相应的整改措施,为同行业的维修人员及技术人员提供参考。
As far as three cases of typical fault occurring to ZYJ7 electro hydraulic switch machine and switching equipment in the signal system of Guangzhou rail transit are analyzed,the causes of the faults have been found out and corresponding measures are put forward in hope of providing reference for maintenance and technical personnel.