期刊文献+

增感屏在9 MeV X射线CR检测中的应用

Application of Intensifying Screen in 9 MeV X-ray CR Detection
下载PDF
导出
摘要 介绍了计算机射线照相技术(CR)和增感屏技术的原理。采用9 MeV直线加速器X射线源、iCR3600+系统和CR UR-1型IP板等,试验了透照不同厚度钢板时,增感屏对IP板成像的增感效果。得到了透照不同厚度钢板时灵敏度最高的增感屏厚度,以为工程应用提供参考。 This paper introduces the principle of the computer radiography technology and intensifying screen.Using 9MeV X-ray accelerator system,iCR3600+and CR UR-1IP board,etc.,the transillumination of steel plate with different thicknesses shows the imaging sensitization effect of the intensifying screen to IP board.Corresponding thicknesses of intensifying screen resulting in the highest sensitivity for steel plate of various thicknesses were obtained,which might provide useful reference for engineering applications.
机构地区 中国人民解放军
出处 《无损检测》 2017年第6期33-35,55,共4页 Nondestructive Testing
关键词 CR系统 IP板 X射线照相 增感屏 CR system image plate X-ray radiography intensifying screen
  • 相关文献

参考文献3

二级参考文献15

  • 1陆先海.CR技术在无损检测领域的有效应用[J].航空制造技术,2006,49(11):54-56. 被引量:5
  • 2郑世才.射线检测[M].北京:机械工业出版社,2004..
  • 3J. Sekita, Industrial X-ray radiography in Japan[J]. INSIGHT, 1998,40(4) :255-259.
  • 4K Marstboom, Computed radiography for corrosion and thickness measurements [J]. INSIGHT, 1999,41 (5) :308-309.
  • 5P Willems,B Vaessen 等,Applicability of computed radiography for corrosion and wall thickness measurements[J]. INSIGHT, 1999,41(10) : 635-637.
  • 6Frederick A. Morro, Computed radiography:the future of radiographic inspection.
  • 7ASTM E2007-00 Standard guide for computed radiology (Photostimulable luminescence(PSL)methed).
  • 8ASTM E2033-99 Standard practice for computed radiology (Photostimulable luminescence (PSL)methed).
  • 9ASTM E2445-05 Standard practice for qualification and long-time stabilitry of computed radiology systems.
  • 10ASTM E2446-05 Standard practice for classification of computed radiology systems.

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部