期刊文献+

不同检测设备对倾点测定结果影响的探讨 被引量:1

Study on the Influence of Different Testing Equipments on Determination Results of Pour Point
下载PDF
导出
摘要 润滑油倾点是反映样品低温流动性的好坏的参数之一,倾点越低,样品的低温流动性越好。在近几年分析样品倾点时,由于全自动倾点测定仪和手动倾点测定仪检测上的差异,有时会出现全自动测定仪与手动测定仪分析结果不一致的现象。文章通过对比全自动倾点测定仪和手动倾点测定仪的分析数据,找出其检测结果的异同,为分析样品倾点提出最佳检测方案。 The pour point of lubricating oil is one of the parameters reflecting the low temperature fluidity of the sample, the lower the pour point, the better the low temperature fluidity of the sample. In recent years, in the analysis of the pour point of sample, due to the difference between automatic pour point analyzer and manual pour point detector, sometimes the re- sults of both methods are inconsistent. In the paper, the similarities and differences of the test results are found out, and the best detection scheme for the pour point of sample are proposed, by comparing the analysis data of the automatic pour point analyzer and the manual pour point detector.
作者 达永娥
出处 《润滑油》 CAS 2017年第3期49-53,共5页 Lubricating Oil
关键词 润滑油 倾点 检测设备 lubricating oil~ pour point~ testing equipment
  • 相关文献

参考文献1

二级参考文献15

  • 1.GB/T 510-83.石油产品凝点测定法[S].,..
  • 2.SY/T 0541—94.原油凝点测定法[S].,..
  • 3.SY/T 5537—2000.原油输送管道运行技术管理规范[S].,..
  • 4.SY/T 6469—2000.原油管道加降凝剂输送工艺技术规范[S].,..
  • 5.GT/T 3535—83(91).石油倾点测定法[S].,..
  • 6.GT/T 2538—88.原油试验法[S].,..
  • 7IP15- 95:Petroleum Products Determination of Pour Point. IP Standard, London, 2001.
  • 8IP411-95:Determination of the Pour Point of Crude Oil, IP Standard, London, 2001.
  • 9ISO 3016- 94:International Standards: Petroleum Products-Determination of Pour Point, International Organization for Standardization, Switzerland, 1994.
  • 10JIS K 2269-87:Japanese Industrial Standard: Testing Method for Pour Point and Cloud Point of Crude Oil and Petroleum Products,Japanese Standards Association, 1987.

共引文献9

同被引文献8

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部