期刊文献+

东部电网大功率直启负荷启动方式分析

Analysis on starting method of high power direct-start load in eastern Heilongjiang power grid
下载PDF
导出
摘要 2017年黑龙江电网东部地区计划投入3台功率较大的直启负荷,为探究其启动过程对电网造成的冲击,采用电力系统分析综合程序对不同的启动组合方式进行仿真分析。建立冲击负荷模型,计算启动过程中几个关键节点的最大电压降落和其波动比例,为电网调度控制及运行方式的编制提供理论依据。 Three high power direct- start loads are scheduled to put into use in eastern Heilongjiang power gnu m 2017. In order to explore the impact on the power grid during starting process, different combinations of starting modes by using PSASP are simulated and analyzed. Also, impact load models are built and ratio of maximum volt- age drop and its offset in some key nodes are calculated during starting process, which provides a theoretical basis for the power grid dispatch and control as well as the establishment of the operation mode.
作者 刘智洋 穆兴华 宋杭选 刘进 陈晓光 曹融 LIU Zhiyang MU Xinghua SONG Hangxuan LIU Jin CHEN Xiaoguang CAO Rong(Electric Power Research Institute of State Grid Heilongjiang Electric Power Co. , Ltd. , Harbin 150030, China)
出处 《黑龙江电力》 CAS 2017年第3期189-192,共4页 Heilongjiang Electric Power
关键词 直启负荷 电力系统分析综合程序 冲击负荷模型 电压降落 运行方式 direct -start load PSASP impact load model voltage drop operation mode
  • 相关文献

参考文献2

二级参考文献5

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部