期刊文献+

公路隧道旁通式净化站气流组织数值模拟及净化效果分析 被引量:3

Numerical Simulation of Air Distribution and Analysis of Purifying Effect of Bypass-type Purification Station in Highway Tunnel
下载PDF
导出
摘要 为分析和解释气流组织对净化站污染处理效果的影响,以常见的旁通式净化站为例,基于FLUENT软件建立包含主隧道和旁通净化风道的数值模型,分析不同来流压力下主隧道和旁通风道的流动规律以及净化效果。研究结果表明,旁通风道风量只取决于设备阻力以及风机性能,与主隧道环境无关;当来流风量小于净化风量时主隧道将发生净流量回流的现象,导致两旁净化风道的负荷不同;当净化风量比为100%时,净化站对污染物的处理效果最佳。 A numerical model based on computational fluid dynamic software FLUENT is established to simulate the air distribution and purifying effect under different air pressures in both the tunnel and the bypass-type purification station.It is shown that:1) The air flow rate of bypass tunnel only depends on the resistance of equipments and fan performance rather than the condition of main tunnel.2) When the upstream air flow rate is less than that of the station,"backflow"phenomenon occurs and results in unbalanced purifying load of the two bypass tunnels.3) When the air flow rate of the station to the main tunnel is 100%,the purifying effect is the best.The study results can provide reference for design and operation of ventilation and purification system of underground works in the future.
作者 林炎顷 常军 李雁 李先庭 LIN Yanqing CHANG Jun LI Yan LI Xianting(Laboratory of Indoor Air Quality Evaluation and Control, School of Architecture, Tsinghua University, Beijing 100084, China Beijing Municipal Engineering Design & Research Institute Co., Ltd., Beijing 100082, China)
出处 《隧道建设》 北大核心 2017年第6期684-690,共7页 Tunnel Construction
基金 国家自然科学基金创新研究群体项目"室内环境营造的基础科学问题"(51521005)
关键词 公路隧道 旁通净化站 空气净化 气流组织 FLUENT highway tunnel bypass-type purification station air purification air distribution FLUENT
  • 相关文献

参考文献9

二级参考文献505

共引文献1080

同被引文献23

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部