B超引导下心电监护定位在新生儿PICC置管中的应用 被引量:15

Clinical studies on the PICC guided by type B ultrasonography and electrocardiography in the newborn
下载PDF
导出
摘要 目的:探讨B超引导下心电监护定位在新生儿PICC置管中的应用效果。方法:将110例行PICC置管的患儿,随机分为观察组和对照组各55例。对照组患儿在B超引导下行PICC置管,观察组患儿在B超引导下联合心电监护定位行PICC置管。通过超声探查和特征性P波的变化确定导管的位置。2组患儿在PICC置管后均行X线片,以检测导管尖端位置。记录并比较2组患儿置管一次性到位率、置管时间及出血量等情况。并以X线片尖端定位作为判定金标准,评估心电图特征性P波预测的准确度。结果:观察组患儿PICC置管一次性到位率(96.36%)高于对照组(83.63%),χ~2=4.946,P<0.05)。观察组置管时间短于对照组出血量少于对照组(P<0.05)。观察组患儿特征性P波预测到位准确度为90.91%,其与X线检测到位情况一致性程度高(Kappa=0.548,P<0.001)。结论 :B超引导下心电监护定位可明显提高PICC置管成功率,并能提高一次性到位率,缩短置管时间,减少出血量。特征性P波预测到位情况与X线检测到位情况一致性程度高。 Objective: To investigate the effect of type-B ultrasonography and electrocardiography on the PICC in the newborn. Methods: A total of 110 newborn received the PICC were selected as research objects and randomly divided into the observation group (n=55) and the control group (n=55). The newborns in control group were inserted under the guidance of type-B uhrasonography, and the newborns in other group were monitored by electrocardiography at the same time. The position of the catheter was detected by uhrasonography and P waves of electrocardiogram. The tip position of the catheter, the one-time success rate, the time of insertion and the amount of bleeding of all newborns in the two groups were recorded and compared. In addition, X-ray was used as a golden standard to assess the accuracy of P wave.Results: The success rate of catheterization of observation group and control groups were 96.36% and 83.63% respectively. It was significantly higher in observation group. The set time and blood loss of observation group were significantly less than that of control group. The prediction accuracy of P waves was 90.91%, the congruence rate of P waves and X-ray detection was good (Kappa=0.548 ,P〈0.001). Conclusion: Type-B ultrasonography combined with electrocardiography can significantly improve the success rate of PICC insertion, and improve the one-time rate, shorten the time of insertion and reduce the amount of bleeding.
作者 靳楠 张凤梅 杨艳华 JIN Nan ZHANG Feng-mei YANG Yan-hua(Affiliated Hospital of Logistics University of PAP, Tianjin 300162 Jizhong Hospital of Energy Fengfeng Group Company)
出处 《天津护理》 2017年第3期199-201,共3页 Tianjin Journal of Nursing
关键词 B超引导 心电监护定位 患儿 PICC置管 Type-B ultrasonography guided Electrocardiography Newborn PICC insertion
  • 相关文献

参考文献7

二级参考文献72

  • 1周和清,扬蓓.PICC的X线分析[J].实用医技杂志,2005,12(08A):2009-2010. 被引量:57
  • 2林真珠,张小园,李丹莹,甘锦红,尹若云.新生儿经颞浅静脉与贵要静脉留置PICC导管效果比较[J].护理学报,2006,13(4):36-37. 被引量:24
  • 3李康明,鞠云鹤,刘燕,张玲玲,秦继勇.经外周插管的中心静脉导管移位胸外侧静脉一例[J].临床误诊误治,2007,20(4):63-64. 被引量:12
  • 4James L,Bledsoe L,Hadaway LC. A retrospective look at tip location and eomplieatlons of peripherally inserted central catheter lines [J]. J lntraven Nurs, 1993,16(2) : 104-109.
  • 5Fricke BL,Racadio JM,Duckworth T,et al. Placement of peripherally inserted central catheters without fluoroscopy in children:initial catheter tip position[J]. Radiology,2005,234(3) :887-892.
  • 6Racadio JM,Doellman DA,Johnson ND,et al. Pediatric peripherally inserted central catheters:complication rates related to catheter tip location[J]. Pediatrics,2001,107(2) :E28.
  • 7Kearns PJ,Coleman S,Wehner JH. Complications of long arm-catheters: a randomized trial of central vs. peripheral tip location [J]. J Parenter Enteral Nutr, 1996,20 ( 1 ) : 20-24.
  • 8Frey AM. Pediatric peripherally inserted central catheter program report:a summary of 4,536 catheter days[J]. J Intraven Nurs,1995,18 (6) :280-291.
  • 9Gamulka B,Mendoza C,Connolly B. Evaluation of a unique,nurseinserted, peripherally inserted central catheter program [ J ]. Pediatrics, 2005,115 (6): 1602-1606.
  • 10Ohki Y,Tabata M,Kuwashima M,et al. Ultrasonographic detection of very thin percutaneous central venous catheter in neonates [J]. Acta Pediatr, 2000,89 ( 11 ) : 1381 - 1384.

共引文献213

同被引文献111

引证文献15

二级引证文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部