期刊文献+

Developing a chloramine decay index to understand nitrification:A case study of two chloraminated drinking water distribution systems 被引量:1

Developing a chloramine decay index to understand nitrification:A case study of two chloraminated drinking water distribution systems
原文传递
导出
摘要 The management of chloramine decay and the prevention of nitrification are some of the critical issues faced by water utilities that use chloramine as a disinfectant.In this study,potential association between high performance size exclusion chromatography(HPSEC)data obtained with multiple wavelength Ultraviolet(UV) detection from two drinking water distribution systems in Australia and nitrification occurrence was investigated.An increase in the absorbance signal of HPSEC profiles with UV detection at λ = 230 nm between apparent molecular weights of 200 to 1000 Da was observed at sampling sites that experienced rapid chloramine decay and nitrification while its absorbance signal at λ =254 nm decreased.A chloramine decay index(C.D.I) defined as the ratio of area beneath the HPSEC spectra at two different wavelengths of 230 and 254 nm,was used in assessing chloramine decay occurrences.The C.D.Is of waters at locations that experienced nitrification were consistently higher than locations not experiencing nitrification.A simulated laboratory study showed that the formation of nitrite/nitrate and/or soluble microbial products and/or the release of extracellular polymeric substances(EPS) during nitrification may contribute to the C.D.I.increase.These findings suggest that C.D.I derived from HPSEC with multiple wavelength UV detection could be an informative index to track the occurrence of rapid chloramine decay and nitrification. The management of chloramine decay and the prevention of nitrification are some of the critical issues faced by water utilities that use chloramine as a disinfectant.In this study,potential association between high performance size exclusion chromatography(HPSEC)data obtained with multiple wavelength Ultraviolet(UV) detection from two drinking water distribution systems in Australia and nitrification occurrence was investigated.An increase in the absorbance signal of HPSEC profiles with UV detection at λ = 230 nm between apparent molecular weights of 200 to 1000 Da was observed at sampling sites that experienced rapid chloramine decay and nitrification while its absorbance signal at λ =254 nm decreased.A chloramine decay index(C.D.I) defined as the ratio of area beneath the HPSEC spectra at two different wavelengths of 230 and 254 nm,was used in assessing chloramine decay occurrences.The C.D.Is of waters at locations that experienced nitrification were consistently higher than locations not experiencing nitrification.A simulated laboratory study showed that the formation of nitrite/nitrate and/or soluble microbial products and/or the release of extracellular polymeric substances(EPS) during nitrification may contribute to the C.D.I.increase.These findings suggest that C.D.I derived from HPSEC with multiple wavelength UV detection could be an informative index to track the occurrence of rapid chloramine decay and nitrification.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第7期170-179,共10页 环境科学学报(英文版)
基金 supported under Australian Research Council's Linkage Projects funding scheme(LP110100459) the provision of in-kind and financial support from the Australian Water Quality Centre(SA Water),Water Corporation(Western Australia),and DCM Process Control
关键词 HPSEC Water distribution systems Nitrification Chloramine decay HPSEC Water distribution systems Nitrification Chloramine decay
  • 相关文献

参考文献2

二级参考文献7

共引文献16

同被引文献2

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部