从地处山西省运城市的夹马口引黄泵站的工程实例出发,通过对含沙水流条件下水泵机组的能耗进行计算,得出了不同含沙水流条件下的水泵机组的单方水耗电量。计算结果表明:当含沙量为1~4 kg/m^3时,24SAP-10型水泵的单方水耗电量低;在含沙量为4~7 kg/m^3时,800S-76型水泵的单方水耗电量低;在含沙量为7~10 kg/m^3时,1200S-76型水泵的单方水耗电量低;当含沙量超过10 kg/m^3时,以上3种泵型水泵的单方水耗电量均急剧增加。根据计算结果,提出了泵站节能运行的措施,以有效降低泵站的运行成本。
Combined with the Jiamakou Pumping Station from Yellow River, at Yuncheng, Shanxi Province, we calculate the power consumption of various pumps that lift silt - laden flow with different concentrations, and obtain unit power consumption under silt - laden flow with different concentrations. The calculation results show that when the sediment concentration is 1 -4 kg/m^3 , 24SAP - 10 type pump has lower unit power consumption; when the sediment concentration is 4 -7 k g / m^3 , 800S - 76 type pump has lower unit power consumption; when the sediment concentration is 7 -10 k g / m^3 , 1200 S - 76 type pump has lower unit power consumption; when the sediment concentration is more than 10kg/m3 , the three kinds of pumps all have a sharp in-crease of unit power consumption. According to the calculation results, we put forward the measures of energy saving operation, so as to reduce the operating cost of the pumping station.
出处
《人民长江》
北大核心
2017年第13期91-94,共4页
Yangtze River
基金
山西省国际合作项目(201603D421011)
2015年山西省水利厅水利技术研究推广项目(2015DSW3)
山西省研究生教育创新项目(2016SY021)
关键词
含沙水流
单方水耗电量
节能运行
能耗
泵站
silt - laden flow
unit power consumption
energy saving operation
energy consumption
Pumping Station