摘要 目的利用CBCT对以S、N、Ba、Cg、PNS 5点构成的10种临床常用的正中矢状参考平面进行比较,评价其准确性,为建立CBCT三维头影测量面部对称性分析系统提供参考。方法选择53例12~20岁面部基本对称的正畸患者,拍摄头颅CBCT片,以10种常用的正中矢状参考平面为基准,分别计算出每位患者的面部不对称指数。结果 10个平面间有显著性差异(P<0.05),标志点到以S、N、Ba确定的正中矢状参考平面的面部不对称指数(11.07±4.15)最小。结论基于CBCT三维头影测量,以S、N、Ba点确定的正中矢状面的准确性最高。 Objective To adopt Cone-beam CT to conduct the comparison among10 midsagittal reference planes which are made by the 5 points S, N, Ba, Cg, PNS, mostly used in the clinical orthodontics, to valuate their accuracy and provide references for the establishment of the CBCT three-dimensional eephalometry facial symmetry analysis system in the future. Methods 53 cases of 12~20- year-old patients with facial symmetry were selected, skull CBCT images were taken, and the facial asymmetry index of each patient was calculated on the basis of 10 kinds of commonly used midsagittal reference planes. Results There was a significant difference among the 10 planes(P〈0.05), and the facial asymmetry index was the smallest of the midsagittal plane determined by S, N and Ba (11.07±4.15). Conclusion Based on the resuhs of the CBCT three-dimensional cephalometry, the accuracy of the midsagittal reference plane determined by the S, N, Ba is the highest one.
作者 王嘉艺 王珊 王林 WANG Jiayi WANG Shan WANG Lin(Jiangsu Key Laboratory of Oral Disease, Nanjing Medical University,Department of Orthodontics ,Affilliated Hospital of Stomatology , Nanjing Medical University, Nanjing 210029, China)
出处 《口腔医学》 CAS 2017年第7期621-624,共4页 Stomatology
基金 国家自然科学基金(81230022) 江苏省临床医学专项(b12014073) 江苏省高校优势学科建设工程资助项目(2014-37)
关键词 CBCT 三维头影测量 对称性 正中矢状参考平面 CBCT three-dimensional cephalometry symmetry midsagittal reference plane
  • 相关文献

参考文献4

二级参考文献44

  • 1贾绮林,黄金芳.后前位X线头影测量分析中正中矢状定位线的评价[J].现代口腔医学杂志,1993,7(2):84-87. 被引量:22
  • 2叶强,穆雄铮,徐海淞,俞哲元,张如鸿,杨娴娴,高晓燕.面部不对称畸形三维重建影像部分骨性标志点三维定位标准的建立[J].组织工程与重建外科杂志,2006,2(3):140-144. 被引量:12
  • 3王红梅,王邦康,纪昌蓉,白玉兴.安氏Ⅲ类偏颌患者下颌对称性分析[J].北京口腔医学,2006,14(4):259-260. 被引量:4
  • 4Hashimoto K,Arai Y,Iwai K,et al.A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine[J].Oral Surg Oral Med Oral Pathol Oral Radiol Endod,2003,95(3):371-377.
  • 5Winter A A,Pollack A S,Frommer H H,et al.Cone beam volumetric tomography vs.medical CT scanners[J].N Y State Dent J,2005,71(4):28-33.
  • 6Erickson GE,Waite DE.Mandibular asymmetry[J].J Am Dent Assoc,1974,89(6):1369-1373.
  • 7Obwegeser HL,Makek MS.Hemimandibular hyperplasia--hemimandibular elongation[J].J Maxillofac Surg,1986,14(4):183-208.
  • 8Subtelny Jd.Early orthodontic treatment[M].Chicago:Quintessence,2000:113-285.
  • 9Danforth R A,Dus I,Mah J.3-D volume imaging for dentistry:a new dimension[J].J Calif Dent Assoc,2003,31(11):817-823.
  • 10Schmid W, Mongini F. A computer - based assessment of structural and displacement asymmetries of the mandible [J]. Am J Orthod Orthop, 1991, 100 (1): 19~34.

共引文献30

同被引文献38

引证文献6

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部